11
Remedy:
- Release the On/Off - switch and remove the grinding container. If fragments of
the grinding material have become stuck between the grinding tool and the guard
ring, do not remove them until after you have disconnected the power cord.
- Fill the grinding container with a sufficient amount of pre-reduced grinding
material.
- Do not exceed the maximum filling hight in any case.
- In the case of hard or tough grinding material, reduce the maximum filling hight
by 50%.
- If the motor circuit breaker has been tripped, you must wait until it switches
back off.
- Wherein the triggered circuit breaker (100-115V version) this will be as described
above with no waiting time is reset.
The motor speed falls sharply or the mill is locked during operation:
Causes:
- The feed granularity is too coarse, ≥ 10 mm.
- There is too much feed material in the grinding container.
- The grinding material is too tough.
- The pulverization tool is being lowered down into the grinding material too
quickly.
Remedy (motor speed falls):
- The speed can be kept at a constant level if the grinding tool is moved slowly
into the grinding material. If the speed drops off, you should not lower the
tool any further. Instead you should raise it again and try to move the tool
slowly into the grinding material at the nominal motor speed.
Remedy (locking):
- Release the On/Off - switch and remove the grinding container. If fragments of the
grinding material have become stuck between the grinding tool and the guard ring,
do not remove them until after you have disconnected the power cord.
Eliminating malfunctions:
The mill does not start up:
Causes:
- Power cord is not plugged into the socket correctly.
- You did not push the On/Off - switch down far enough.
- The grinding container is not screwed in up to the stop (when you press the On/
Off - switch the malfunction display lights up).
- The mill has been heated up by the previous grinding procedure (the malfunction
display lights up when you press the On/Off - switch).
- After disassembling the middle section (for example to clean it) the switch block
is not completely engaged.
- Circuit breaker tripped (only 100-115V version).
Remedy:
- If necessary, check the power supply and the power cord.
- Push the On/Off - switch down until a „click“ is audible.
- Reset circuit breaker (only 100-115V version).
If the malfunction display lights up when you push the On/Off - switch:
- Screw the grinding container up to the stop (a soft „Click“ is audible) and if
necessary remove any dirt from the threading.
- Check to make sure the switch block is engaged in place.
- If the mill has overheated, wait a few minutes for it to cool down.
The motor is locked after the On/Off - switch has been pressed, or the
mill switches off shortly after it has started.
Causes:
- Too much grinding material in the grinding container (filling hight exceeded).
- The feed granularity is too coarse.
- Motor circuit breaker is tripped because of lock (overload).