background image

SP209 Series User Manual

SP209 / SP209i

• Ensure the USB port used can deliver at least 500mA.

• Try switching to another machine if one is available.

• If all of the above fails, please contact Ikalogic support.

Capturing your first signal

To capture your first logic signals, please follow these steps:

1. Connect the device via USB

2. Launch ScanaStudio and create an SP209(i) workspace.

3. Connect the probes to SP209(i) and to your signals source

4. Ensure the ground probe is connected

5. Check if the status LED is blinking: if it’s the case, it means the some logic changes are already

being detected on the probes.

6. Hit the start button in ScanaStudio and wait until signals are captured.

You can adjust the capture duration by adjusting the number of samples in the device configuration

tab.

Mechanical data

All SP209 series devices casing are manufactured from anodized aluminum, able to withstand heavy

duty usage in various harsh environments. All markings are laser engraved, ensuring important pinout

information is not lost over time.

(c) Ikalogic SAS 2019

15/23

Summary of Contents for SP209 Series

Page 1: ...SP209 series datasheet and user manual SP209 and SP209i 9 channels 200 MSPS logic analyzer with industrial inputs option www ikalogic com support ikalogic com December 28 2020...

Page 2: ...g 9 Versatile trigger system 9 External trigger OUT specifications 10 External trigger IN specifications 11 Industrial port SP209i only 11 RS485 receiver specifications 12 RS232 receiver specification...

Page 3: ...ion and customer support 19 Accessories and maintenance 19 Certifications and regulations 19 Safety information 21 Symbols definitions 21 Important safety notes 21 Limited warranty limitation of liabi...

Page 4: ...al receivers for CAN LIN RS232 and RS485 buses 1 Figure 1 SP209 Logic Analyzer Figure 2 sp209i logic analyzer industrial version Typical applications SP series logic analyzers are perfectly adapted fo...

Page 5: ...tured and analyzed by SP209 logic analyzer Product highlights Schmitt trigger input stages with adjustable thresholds 200 MHz sampling rate with all 9 channels used External clock option state mode up...

Page 6: ...SP209 Series User Manual SP209 SP209i Warning Read safety information section carefully before using this instrument c Ikalogic SAS 2019 6 23...

Page 7: ...ory 2 Gb Trigger output Yes via SMA connector External trigger input Yes via SMA connector Logic inputs specifications Number of channels 9 Input impedance 200 K 8 pF Threshold circuits 3 Adjustable l...

Page 8: ...c analyzer ports and interfaces are shown in the diagram below Figure 4 SP209i ports and interfaces 1 Status LED 2 9 CH logic probes input 3 Trigger OUT SMA connector 4 Trigger IN SMA connector 5 USB...

Page 9: ...it has the disadvantage of limiting the sampling rate to USB s throughput SP209 combines the advantages of both streaming and embedded memory techniques An embedded 2Gb DDR 3 memory stores captured sa...

Page 10: ...re is an internal data path delay of 20ns before external signals reach internal trigger engine T0 When trigger event occurs 10ms T2 pulse is generated on the Trig Out port This port has a 50 series i...

Page 11: ...ic channels which can only be connected to single ended logic level such as LVCMOS or LVTTL Each one of the industrial inputs integrates a dedicated receiver circuit perfectly adapted to each standard...

Page 12: ...mum 15 V Differential Threshold voltage 125 mV Differential Fixed hysteresis 25 mV Differential Input Impedance 400 k or 120 Software selectable RS232 receiver specifications Transceiver MPN Maxim MAX...

Page 13: ...ng range BAT pin 6 V to 18 V Operating range RX pin 0 V to 18 V RX pull up resistance to BAT 40 k Absolute max voltage BAT 24 V Absolute max voltage RX 24 V Threshold voltage 0 5 x VBAT Hysteresis 0 1...

Page 14: ...re White blinking Device powered up connected to software and detecting activity on one of the logic channels Software Quick Start guide Start by downloading the latest version of ScanaStudio software...

Page 15: ...s source 4 Ensure the ground probe is connected 5 Check if the status LED is blinking if it s the case it means the some logic changes are already being detected on the probes 6 Hit the start button i...

Page 16: ...SP209 Series User Manual SP209 SP209i Model SP209i Weight 105 gm Figure 7 SP209i dimensions mm c Ikalogic SAS 2019 16 23...

Page 17: ...SP209 Series User Manual SP209 SP209i Model SP209 Weight 90 g Figure 8 SP209 dimensions mm c Ikalogic SAS 2019 17 23...

Page 18: ...ables are made of 24AWG extra flexible silicone wires All wires are black colored but every wire has a white marking tube with the channel number e g 1 or GND and a colored sticker on the probe tip Fi...

Page 19: ...w Voltage Directive 2006 95 EC IEC 61326 2 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and...

Page 20: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and re...

Page 21: ...WEEE logo This product complies with the WEEE Directive 2002 96 EC marking require ments The affixed label indicates that you must not discard this electrical electronic product in domestic household...

Page 22: ...ove the rating of the instrument 25V Measure a known voltage first to make sure that the product operates correctly Do not work alone Comply with local and national safety codes Use personal protectiv...

Page 23: ...ding will not affect the validity or enforceability of any other provision Document Revisions 30 June 2019 Updated safety information section Added Ordering information and customer support section Ad...

Reviews: