background image

SP209 Series User Manual

SP209 / SP209i

EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY

OR FITNESS FOR A PARTICULAR PURPOSE. IKALOGIC SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,

INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF DATA, WHETHER ARISING

FROM BREACH OF WARRANTY OR BASED ON CONTRACT, TORT, RELIANCE OR ANY OTHER THEORY. Since

some countries or states do not allow limitation of the term of an implied warranty, or exclusion or

limitation of incidental or consequential damages, the limitations and exclusions of this warranty may

not apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court of

competent jurisdiction, such holding will not affect the validity or enforceability of any other provision.

Document Revisions

30-June-2019

Updated safety information section

Added Ordering information and customer support section

Added Accessories and maintenance section

Added Limited warranty & limitation of liability section

04-February-2019

Added SP209i integrated transceivers Manufacturer Part Numbers

Updated T.B.D. parameters for the SP209i CAN transceiver

Added specifications related to the CAN and LIN transceivers

Changed trigger output voltage high level from 5V to 3.3V

01-February-2019

Moved from preliminary to final release.

Fixed spelling error in quick start section

22-November-2018

Fixed error in “What’s in the box” chapter.

Updated trigger OUT and trigger IN specifications.

Updated device weight.

10-October-2018

Initial release of this document.

The information in this document is subject to change without notice.

(c) Ikalogic SAS 2019

23/23

Summary of Contents for SP209 Series

Page 1: ...SP209 series datasheet and user manual SP209 and SP209i 9 channels 200 MSPS logic analyzer with industrial inputs option www ikalogic com support ikalogic com December 28 2020...

Page 2: ...g 9 Versatile trigger system 9 External trigger OUT specifications 10 External trigger IN specifications 11 Industrial port SP209i only 11 RS485 receiver specifications 12 RS232 receiver specification...

Page 3: ...ion and customer support 19 Accessories and maintenance 19 Certifications and regulations 19 Safety information 21 Symbols definitions 21 Important safety notes 21 Limited warranty limitation of liabi...

Page 4: ...al receivers for CAN LIN RS232 and RS485 buses 1 Figure 1 SP209 Logic Analyzer Figure 2 sp209i logic analyzer industrial version Typical applications SP series logic analyzers are perfectly adapted fo...

Page 5: ...tured and analyzed by SP209 logic analyzer Product highlights Schmitt trigger input stages with adjustable thresholds 200 MHz sampling rate with all 9 channels used External clock option state mode up...

Page 6: ...SP209 Series User Manual SP209 SP209i Warning Read safety information section carefully before using this instrument c Ikalogic SAS 2019 6 23...

Page 7: ...ory 2 Gb Trigger output Yes via SMA connector External trigger input Yes via SMA connector Logic inputs specifications Number of channels 9 Input impedance 200 K 8 pF Threshold circuits 3 Adjustable l...

Page 8: ...c analyzer ports and interfaces are shown in the diagram below Figure 4 SP209i ports and interfaces 1 Status LED 2 9 CH logic probes input 3 Trigger OUT SMA connector 4 Trigger IN SMA connector 5 USB...

Page 9: ...it has the disadvantage of limiting the sampling rate to USB s throughput SP209 combines the advantages of both streaming and embedded memory techniques An embedded 2Gb DDR 3 memory stores captured sa...

Page 10: ...re is an internal data path delay of 20ns before external signals reach internal trigger engine T0 When trigger event occurs 10ms T2 pulse is generated on the Trig Out port This port has a 50 series i...

Page 11: ...ic channels which can only be connected to single ended logic level such as LVCMOS or LVTTL Each one of the industrial inputs integrates a dedicated receiver circuit perfectly adapted to each standard...

Page 12: ...mum 15 V Differential Threshold voltage 125 mV Differential Fixed hysteresis 25 mV Differential Input Impedance 400 k or 120 Software selectable RS232 receiver specifications Transceiver MPN Maxim MAX...

Page 13: ...ng range BAT pin 6 V to 18 V Operating range RX pin 0 V to 18 V RX pull up resistance to BAT 40 k Absolute max voltage BAT 24 V Absolute max voltage RX 24 V Threshold voltage 0 5 x VBAT Hysteresis 0 1...

Page 14: ...re White blinking Device powered up connected to software and detecting activity on one of the logic channels Software Quick Start guide Start by downloading the latest version of ScanaStudio software...

Page 15: ...s source 4 Ensure the ground probe is connected 5 Check if the status LED is blinking if it s the case it means the some logic changes are already being detected on the probes 6 Hit the start button i...

Page 16: ...SP209 Series User Manual SP209 SP209i Model SP209i Weight 105 gm Figure 7 SP209i dimensions mm c Ikalogic SAS 2019 16 23...

Page 17: ...SP209 Series User Manual SP209 SP209i Model SP209 Weight 90 g Figure 8 SP209 dimensions mm c Ikalogic SAS 2019 17 23...

Page 18: ...ables are made of 24AWG extra flexible silicone wires All wires are black colored but every wire has a white marking tube with the channel number e g 1 or GND and a colored sticker on the probe tip Fi...

Page 19: ...w Voltage Directive 2006 95 EC IEC 61326 2 This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and...

Page 20: ...nd on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and re...

Page 21: ...WEEE logo This product complies with the WEEE Directive 2002 96 EC marking require ments The affixed label indicates that you must not discard this electrical electronic product in domestic household...

Page 22: ...ove the rating of the instrument 25V Measure a known voltage first to make sure that the product operates correctly Do not work alone Comply with local and national safety codes Use personal protectiv...

Page 23: ...ding will not affect the validity or enforceability of any other provision Document Revisions 30 June 2019 Updated safety information section Added Ordering information and customer support section Ad...

Reviews: