3.2 Interconnection Cable Requirements
To connect the Local and Remote units you will need:
•
CATx Modules:
S/UTP (CAT5) cable acc. to EIA/TIA 56A or TSB 36 or Digital
STP 17-03170. Four pairs AWG 24. Pinout acc. EIA/TIA 568A (10BaseT).
Screen must be connected on both ends. Please ensure that the connection is
tension-free.
•
Fibre Cables:
Multimode:
Two fibres 50
µ
m or 62.5
µ
m. E.g. I-V(ZN)H 2G50 (In
house patch cable)or I-V(ZN)HH 2G62,5 (In house Breakout cable) or
I/AD(ZN)H 4G50 (in house OR outdoor Breakout cable, stress
resistant) or A/DQ(ZN)B2Y 4G62,5 (outdoor cable, stress resistant
with protection against animal biting) All notations acc. VDE
specification.
Singlemode:
Two fibres 9
µ
m. E.g. I-V (ZN)H 2E9 (In house patch
cable) or I-V(ZN)HH 2E9 (In house Breakout cable) or I/AD(ZN)H 4E9
(in house OR outdoor Breakout cable, stress resistant) or
A/DQ(ZN)B2Y 4G9 (outdoor cable, stress resistant with protection
against animal biting) All notations acc. VDE specification.
A point to point connection is required. Having one or more patch
panels in the line is possible and allowed. Not allowed is a
connection from the fibre link interface to any other products,
especially telecommunications or network equipment.
•
DVI, PS/2-Keyboard, PS/2-Mouse:
Connect the supplied KVM CPU cable set
to your CPU (KVM.- Switch, etc.). Please ensure that the connection is tension-
free! Devices K455-1W + K455-2W
•
DVI, USB-Keyboard, USB-Mouse:
Connect the supplied KVM CPU cable set to
your CPU (KVM.- Switch, etc.). Please ensure that the connection is tension-
free! Devices K455-1U + K455-2U
•
DVI:
Connect the supplied DVI CPU cable set to your CPU (KVM - Switch, etc.).
Please ensure that the connection is tension-free! Devices K455-2W + K455-2U
•
VGA Input:
If you are using a VGA graphic source please use the delivered
DVI/VGA adapter.
•
VGA Output:
If you are using a VGA monitor please use the delivered VGA/DVI
adapter.
•
Power Supply:
Connect the supplied 6V/DC power supplies to the
Plug
terminal on the rear of both Local and Remote units.
USB devices have an additional power supply. You need to attach this PSU to
the Remote unit if the total power consumption of the attached USB devices
exceeds 500mA (see
Appendix E: USB – High Power/Low Power
).