background image

9

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

General Information

900608-00,  01/2019

Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces

Figure 6

EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS 

Fixed

Closed

Openable Fixed

Closed

V

V

V

V

V

V

X

X

V

X

G

G

J

F

B

B

K

H

I

A

E

L

D

B

M

C

B

V

V

A

G

G

B

TERMINATION CAP

AIR SUPPLY INLET

GAS METER

RESTRICTED AREA

(TERMINATION PROHIBITED)

Openable

See 

Figure 4

V

V

Inside Corner

V

V

Outside Corner

Recessed Location

Balcony with No Side Wall

V

Balcony with Perpendicular Side Wall

G

F

M

M

N

P

O

Q

U.S. Installation **

Canadian Installation *

A

Clearance above grade, veranda, porch, desk, or balcony

12” (300 mm) **

12” (300 mm) *

B

Clearance to window or door that may be opened

6” (150 mm)  

for fireplaces < 10,000 Btu/h (3 kW), 
9” (230 mm) 

for fireplaces > 10,000 Btu/h (3 kW), and < 50,000 Btu/h (15 

kW), 
12” (300 mm)  

for fireplaces > 50,000 Btu/h (15 kW) **

6” (150 mm)  

for fireplaces < 10,000 Btu/h (3 kW), 
12” (300 mm)  

for fireplaces > 10,000 Btu/h (3 kW)

C

Clearance to permanently closed window

9” (229 mm)  

recommended to prevent window condensation

12” (305 mm)  

recommended to prevent window 

condensation

D

Vertical clearance to ventilated soffit located above the 

termination within a horizontal distance of 18” (458 mm)

18” (458 mm)

18” (458 mm)

E

Clearance to unventilated soffit

12” (305 mm) 

12” (305 mm) 

F

Clearance to outside corner

5” (127 mm)  

minimum

5” (127 mm)  

minimum

G

Clearance to inside corner

6” (152 mm) minimum

6” (152 mm) minimum

H

Clearance to each inside of center line extended above 

meter / regulator assembly

36” (910 mm)  

within a height of 15 ft above the meter / regulator assembly **

36” (910 mm)  

within a height of 15 ft above the meter / 

regulator assembly *

I

Clearance to service regulator vent outlet

36” (910 mm)**

36” (910 mm)*

J

Clearance to non-mechanical air supply inlet to building or 

the combustion air inlet to any other fireplace

6” (150 mm)  

for fireplaces < 10,000 Btu/h (3 kW), 
9” (230 mm)  

for fireplaces > 10,000 Btu/h (3 kW) and < 50,000 Btu/h (15 kW), 
12” (300 mm)  

for fireplaces > 50,000 Btu/h (15 kW)**

6” (150 mm)  

for fireplaces < 10,000 Btu/h (3 kW), 
12” (300 mm)  

for fireplaces > 10,000 Btu/h (3 kW)

K

Clearance to a mechanical air supply inlet

36” (910 mm) above if within 10 ft (3 m) horizontally **

72” (1830 mm) *

L

Clearance above paved sidewalk or paved driveway located 

on public property

84” (2130 mm) ‡

84” (2130 mm) ‡

M

Clearance under veranda, porch, deck or balcony

12” (300 mm) *‡

12” (300 mm) *‡

N

Depth of alcove (maximum)

72” (1830 mm) **

72” (1830 mm) *

O

Clearance to termination (alcove)

6” (15.2 mm) **

6” (15.2 mm)*

P

Width of alcove (minimum)

36” (910 mm) **

36” (910 mm) *

Q

Clearance to combustible above (alcove)

18” (457 mm) **

18” (457 mm) *

*

**

*‡

In accordance with the current CAN/CGA-B149.1 National Gas And Propane Installation Code
In accordance with the current ANSI Z223.1/NFPA 54 National Fuel Gas Codes
A vent shall not terminate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings
Only permitted if veranda, porch, deck, or balcony is fully-open on a minimum two sides beneath the floor

f i r e - p a r t s . c o m

Summary of Contents for Superior Fireplaces MHD40STDMN

Page 1: ...entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future refe...

Page 2: ...VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de conta...

Page 3: ...uras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el con...

Page 4: ...5 oneventrestrictortobeappliedasshownon Page16 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies 8 one fuel conversion kit Nat Gas to LP Gas locatedinthebottomcontrolcompartment NOTE I...

Page 5: ...odesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CAN CGA B149 1 The appliance when installed mu...

Page 6: ...gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements IntheCommonwealthofM...

Page 7: ...factured Home Construction and Safety Standard Title 24 CPF Part 3280 ou la norme CAN CSA Z240 S rie MM Maisons Mobiles Manufactured Home installations must be installed in accordance with these instr...

Page 8: ...nt Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figure 3 NOTE See Figure 36 on Page 24 for the exterior wall recess allowances of the squ...

Page 9: ...de corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 9...

Page 10: ...ppliance face with these exceptions they must not cover any portion of the removable glass panel or control compartment Vertical installation clearances to combustible mantels vary according to the de...

Page 11: ...loor 0 0 FromBottomof Unit To Ceiling 64 1626 Vent 3 77 Top 1 26 Sides Bottom SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification Top View of...

Page 12: ...provided and bring in the electrical service line Step 6 Page 30 Make connection to gas supply Step7 Page31 Verifyingapplianceoperation Step 8 Page 31 Install the logs decorative volcanic stone and g...

Page 13: ...his dimension based on 5 8 drywall For 1 2 drywall use 23 Provide Additional Space For Side Vent Seal Cap If Installing Against A Solid Wall 10 1 2 12 1 8 5 1 8 Figure 14 Figure 13 FIREPLACE FRAMING S...

Page 14: ...40 1 4 1022 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Stepped to accept drywall o...

Page 15: ...p 6 on Page 30 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certainlyno one unfam...

Page 16: ...exigences du foumisseunde gaz Use only approved venting components See Approved Vent Components on Page 4 These fireplaces must be vented directly to the outside The vent system may not service multip...

Page 17: ...1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0...

Page 18: ...onent to a length of ventrun alignthedimpledendovertheinclined channel end of the previously installed section adjusting the radial alignment until the four locking dimples are aligned with the inlets...

Page 19: ...8 feet 2 4 m Maximum 1 26 mm minimum clearance to combustibles Figure 24C Another method where the vent is not adjacent toawall isillustratedinFigure24D Here sup portstraps 96K93 andsupportplates 96K9...

Page 20: ...htheterminationdownuntilitfullyengages thentwisttheterminationclockwiserunningthe dimples down and along the incline channels until they seat at the end of the channels I Install the roof flashing Ext...

Page 21: ...1 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4...

Page 22: ...Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H1 Maximum V Mini...

Page 23: ...ccurintheceilingorroofjoists Allowforelbows as indicated in Figure 25 on Page 19 Maintain a minimum 1 26 mm clearance to combustiblesontheverticalsections Clearances for the horizontal runs are 3 77 m...

Page 24: ...articular range of wall thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the...

Page 25: ...ratios that are smaller are acceptable all the way down to at or near level NOTE SV4 5VF SecureVent SF4 5VF SecureFlex firestop spacermust be used anytime vent pipe passes through a combustible floor...

Page 26: ...quired ThisTableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum feet meter fee...

Page 27: ...H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent THREE 90 DEGREE E...

Page 28: ...he way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 from the end 3 Pull and extend the inner flexible vent pipe 4 Slidethei...

Page 29: ...cancauseimproperanddangerous operation ATTENTION Aumomentdel entretien descommandes tiqueteztouslesfils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonc tionnement inad quat et...

Page 30: ...is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas flex lineforuse wherepermitted inconnectin...

Page 31: ...y so that none of the wires become loose or disconnected Step 7 VERIFYING APPLIANCE OPERA TION MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure 50 Figure 51 Piezo I...

Page 32: ...shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter gap should be decreased Sooting is caused by incomplete combustion in the flames and lack of combustion ai...

Page 33: ...e 53 2 Light appliance follow lighting procedure on lighting label in control compartment or see the Installation and Operation Manual 3 Allow the burner to operate for at least 15 minutes while obser...

Page 34: ...his Area Must Remain Clear of Combustible Materials 3 77 mm Top Spacers Header Step 11 INSTALL FRONT FACE Install front face assembly with barrier Step 12 HOOD INSTALLATION Refer to Figure 55 All of t...

Page 35: ...e fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re etlestracesdegrai...

Page 36: ...ure Vent Components Cat No Model Description H1968 SV4 5HT 2 HorizontalSquareTermina tion With Firestop spacer H2246 Adaptor 74L61 H2152 SV4 5CGV 1 Vertical Termination Cap High Wind Vent Sections Rig...

Page 37: ...52M H2248 SF4 5HF 10 Firestop Spacer Hori zontal flex 3 1 1spacing 10 Pack H2249 SF4 5VF 10 Firestop Spacer Vertical flex 1 1 1 spacing 10 Pk 56L74 SFVT30 Vertical Termination for flex flat to 6 12 wi...

Page 38: ...ly so that none of the wires become loose or disconnected d Locate the two 2 latches at the top of the control compartment To disengage the two latches from the bottom vee flange of the glass enclosur...

Page 39: ...for natural and propane models Figure 59 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 60 Ensure that the arm of the venturi of the burn...

Page 40: ...ter des br luresouqueleursv tements ne s enflamment WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de v tements ni d...

Page 41: ...y to the left away from the fireplace Refer to Figure 62 for access to the gas control valve Millivolt appliances will be fitted with the gas control valve shown in Figure 62 Familiarize yourself with...

Page 42: ...menea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoro eltermostatodeparedparaquitarelpolvoyaceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Fi...

Page 43: ...aware of shrubs and plantings that may encroach on the termination The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techn...

Page 44: ...oors certified with the appliance shall be used Seules des portes certifi es pour cet appareil doivent tre utilis es These are direct vent appliances They are designed to operate only when the front g...

Page 45: ...Figure 65 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material 5 Place Volcanic Stone Spread volcanic stone evenly over firebox floor 6 Install Ve...

Page 46: ...ard Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of...

Page 47: ...1 3 Figure 67 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face The Front Position Th...

Page 48: ...shutter opening will need to be An appliance operated with the air shutter opened too far may have flames that appear blue and transparent These weak blue and transparent flames are termed anemic Prop...

Page 49: ...parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The inst...

Page 50: ...wall mounted or placed in the valve compartment Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in F and C Connects to...

Page 51: ...er Kits Cat No Model No Description H0778 EBLK PF MHD40PF H0779 EBLK ST MHD40ST OFF ON Wall Switch Kit TheOFF ONwallswitchkitmaybeusedtocontrolthe operation of the fireplace burner Install the OFF ON...

Page 52: ...used by long lateral runs too many elbows and or exterior portions of the systembeingexposedtocoldweather Alsoinspectwallstraps or plumbers s tape to ensure it is secure and in place Appliance Checkou...

Page 53: ...immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call...

Page 54: ...imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technic...

Page 55: ...shooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 50 on Page 31 Check burner orifice for stop...

Page 56: ...Face Assembly with Barrier J7531 0 1 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in proper...

Page 57: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Page 58: ...Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices a...

Reviews: