Installation

900608-00  01/2019

Innovative Hearth Products
MHD40 Series Multi-View Direct-Vent Gas Fireplaces

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE

35

Illustrations are for example only. 

Your accessories may be different.

Les illustrations sont par exemple 

uniquement. Vos accessoires 

peuvent être différents.

Las ilustraciones son sólo ejemplos. 

Tu accesorios pueden ser diferentes.

ATTACHING SAFETY IN OPERATION WARNINGS 

It is required that the safety instruction labels 

furnished with the fireplace be affixed to the opera-

tion and control point of the fireplace.  A safety 

instruction label must be affixed to the wall switch 

plate where the fireplace is turned on and off 

(See 

Figure A

)

 or wall thermostat 

(See 

Figure B

)

 and if 

used on the remote control handheld transmitter 

(

Figure C

)

.  To properly complete the installation 

of this fireplace, locate the multi-lingual adhesive 

labels provided with the Care and Operation 

Instructions and proceed as follows:
1.  Locate the wall switch or wall thermostat that 

controls the fireplace (verify the switch operates 

the fireplace by turning it on and off).  Clean the 

wall switch plate or wall thermostat thoroughly 

to remove any dust and oils. Affix the label to 

the surface of the plate of the wall switch that 

controls the fireplace 

(

Figure A

)

 or the wall 

thermostat 

(

Figure B

)

.   Choose the language 

primarily spoken in the home. If unknown, affix 

the English language label.

2. If a remote control is used to control the 

fireplace, locate the transmitter and clean it 

thoroughly to remove any dust and oils.  Affix 

the label to the surface of handheld transmitter 

(

Figure C

)

.   Choose the language primarily 

spoken in the home. If unknown, affix the 

English language label.

3.  If you are unable to locate the labels, please 

contact IHP or your nearest IHP dealer to 

receive additional safety instruction labels free 

of charge.

Cat. No. H8024 Replacement Label Kit 

IHP

SuperiorFireplaces.us.com

NOTE: English is red text on clear label. French 

and Spanish are white text on black label.

STEP 13.  ATTACHING SAFETY-IN-OPERATION WARNINGS
It is the installers responsibility to ensure these warnings are properly affixed during installation. These warning labels are a 

critical step in informing consumers of safe operation of this appliance.

APPOSITION DES MISES EN GARDE RELATIVES 

À LA SÉCURITÉ D’UTILISATION 

Il est impératif que les étiquettes de sécurité fournies 

avec le foyer soient collées à côté des dispositifs de 

contrôle du foyer.  Une étiquette de sécurité doit 

être collée sur la plaque de l’interrupteur contrôlant 

l’allumage du foyer 

(voir 

Figure A

)

 ou sur le thermostat 

mural 

(voir 

Figure B

)

 et, le cas échéant, sur le boîtier  

de la télécommande 

(

Figure C

)

. Pour achever 

l’instal lation correcte de ce foyer, procédez comme 

suit avec les étiquettes adhésives en langues 

étrangères fournies avec les instructions d’utilisation 

et d’entretien :
1.  Repérez l’interrupteur ou le thermostat mural qui  

contrôle le foyer (vérifiez que l’interrupteur 

contrôle le fonctionnement du foyer en le faisant 

basculer de Marche à Arrêt, et vice-versa). Nettoyez 

soigneusement la plaque murale de l’interrupteur 

ou le thermostat mural pour éliminer la poussière 

et les traces de graisse ou d’huile. Collez l’étiquette 

sur la surface de la plaque de l’interrupteur mural 

qui contrôle le foyer 

(

Figure A

)

 ou du thermostat 

mural 

(

Figure B

)

. Choisissez la langue qui est 

principalement parlée dans la résidence du 

propriétaire. En cas de doute, collez l’étiquette 

en anglais.

2.  Si une télécommande est utilisée pour contrôler 

le foyer, nettoyez la soigneusement pour éliminer 

la poussière et les traces de graisse ou d’huile.   

Collez l’étiquette sur le boîtier de la télé-

commande 

(

Figure C

)

. Choisissez la langue qui est  

principalement parlée dans la résidence du proprié-

taire. En cas de doute, collez l’étiquette en anglais.

3.   Si vous ne parvenez pas à localiser les étiquettes, 

s’il vous plaît contactez IHP ou votre revendeur 

le plus proche pour recevoir IHP étiquettes 

d’instructions de sécurité supplémentaires 

gratuitement.
Étiquettes de remplacement, n° cat. H8024 

IHP

SuperiorFireplaces.us.com

Remarque : Le texte anglais est rouge sur un 

support transparent. Le texte français et espagnol 

est blanc sur un support noir.

COLOCACIÓN DE ADVERTENCIAS DE SEGURIDAD 

EN OPERACIÓN 

Se requiere que las etiquetas de instrucciones de 

seguridad incluidas con la chimenea se coloquen en 

el punto de operación y control de la misma. Se debe 

colocar una etiqueta de instrucciones de seguridad 

en la placa del interruptor de pared desde el cual se  

enciende y se apaga la chimenea 

(ver la 

Figura A

)

 

o en el termostato de pared 

(ver la 

Figura B

)

 y en 

el transmisor de control remoto 

(

Figura C

)

 si se 

usa. Para completar correctamente la instalación de 

esta chimenea, encuentre las etiquetas adhesivas 

multilingües incluidas con las instrucciones de cuidado 

y operación y haga lo siguiente:
1.  Identifique el interruptor o el termostato de pared 

que controla la chimenea (verifique que el interruptor 

opera la chimenea encendiéndola y apagándola). 

Limpie bien la placa del interruptor o el termostato  

de pared para quitar el polvo y aceite. Pegue la 

etiqueta en la superficie de la placa del interruptor 

que controla la chimenea 

(

Figura A

)

 o en el 

termostato de pared 

(

Figura B

)

.

 

Seleccione el 

idioma que más se habla en la casa. Si no sabe 

cuál es, use la etiqueta en inglés.

2.  Si se usa un control remoto para controlar la 

chimenea, encuentre el transmisor y límpielo bien 

para quitar el polvo y aceite. Pegue la etiqueta en 

la superficie del transmisor 

(

Figura C

)

.

 

Seleccione 

el idioma que más se habla en la casa. Si no sabe 

cuál es, use la etiqueta en inglés.

3.  Si usted es incapaz de localizar las etiquetas, por 

favor póngase en contacto con IHP, o con su 

distribuidor más cercano IHP recibir instrucción 

etiquetas de seguridad adicionales sin costo. 

Juego de etiquetas de repuesto - Nº de cat. H8024 

IHP

SuperiorFireplaces.us.com

Nota: La etiqueta en inglés es transparente con texto 

rojo. Las etiquetas en francés y español son negras 

con texto blanco.

SAFETY LABEL  

DIAGRAMS

DIAGRAMAS DE ETIQUETAS  

DE SEGURIDAD

DIAGRAMMES DES ÉTIQUETTES

DE SÉCURITÉ

Figure A

Figure B

Figure C

Figura A

Figura B

Figura C

f i r e - p a r t s . c o m

Summary of Contents for Superior Fireplaces MHD40STDMN

Page 1: ...entretiendoivent treassur spar un installateur ou un service d entretien qualifi ou par le fournisseur de gaz INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future refe...

Page 2: ...VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas de conta...

Page 3: ...uras graves si se toca Mantenga a los ni os alejados de la chimenea en funcionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el con...

Page 4: ...5 oneventrestrictortobeappliedasshownon Page16 restrictoristapedtotheenvelope 6 barriers 7 front face assemblies 8 one fuel conversion kit Nat Gas to LP Gas locatedinthebottomcontrolcompartment NOTE I...

Page 5: ...odesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition or the Natural Gas and Propane Instal lation Code CAN CGA B149 1 The appliance when installed mu...

Page 6: ...gas line connector used shall not exceed 36 inches 92 centimeters in length The individual manual shutoff must be a T handle type valve Massachusetts Horizontal Vent Requirements IntheCommonwealthofM...

Page 7: ...factured Home Construction and Safety Standard Title 24 CPF Part 3280 ou la norme CAN CSA Z240 S rie MM Maisons Mobiles Manufactured Home installations must be installed in accordance with these instr...

Page 8: ...nt Termination Clearances Terminatemultipleventterminationsaccordingto the installation codes listed above and Figure 3 NOTE See Figure 36 on Page 24 for the exterior wall recess allowances of the squ...

Page 9: ...de corner 6 152 mm minimum 6 152 mm minimum H Clearance to each inside of center line extended above meter regulator assembly 36 910 mm within a height of 15 ft above the meter regulator assembly 36 9...

Page 10: ...ppliance face with these exceptions they must not cover any portion of the removable glass panel or control compartment Vertical installation clearances to combustible mantels vary according to the de...

Page 11: ...loor 0 0 FromBottomof Unit To Ceiling 64 1626 Vent 3 77 Top 1 26 Sides Bottom SERVICE CLEARANCES Feet meters Front Back Sides 3 feet 0 9 meters Table 5 Figure 10 Unit Parts Identification Top View of...

Page 12: ...provided and bring in the electrical service line Step 6 Page 30 Make connection to gas supply Step7 Page31 Verifyingapplianceoperation Step 8 Page 31 Install the logs decorative volcanic stone and g...

Page 13: ...his dimension based on 5 8 drywall For 1 2 drywall use 23 Provide Additional Space For Side Vent Seal Cap If Installing Against A Solid Wall 10 1 2 12 1 8 5 1 8 Figure 14 Figure 13 FIREPLACE FRAMING S...

Page 14: ...40 1 4 1022 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top Stepped to accept drywall o...

Page 15: ...p 6 on Page 30 Installingagassupplylinefromthefuelsupplyto theapplianceinvolvesnumerousconsiderations of materials protection sizing locations con trols pressure sediment andmore Certainlyno one unfam...

Page 16: ...exigences du foumisseunde gaz Use only approved venting components See Approved Vent Components on Page 4 These fireplaces must be vented directly to the outside The vent system may not service multip...

Page 17: ...1 6 0 7 5 2 3 2 5 7 3 9 1 0 0 0 0 5 5 7 3 2 5 7 9 1 1 0 0 0 5 6 5 1 4 2 5 2 1 0 2 0 0 0 7 0 7 6 4 2 5 0 2 1 0 0 7 0 8 2 5 2 1 2 0 1 0 7 0 8 4 6 2 2 2 0 0 1 7 0 8 6 7 2 3 2 0 0 0 8 0 8 9 7 2 5 2 3 2 0...

Page 18: ...onent to a length of ventrun alignthedimpledendovertheinclined channel end of the previously installed section adjusting the radial alignment until the four locking dimples are aligned with the inlets...

Page 19: ...8 feet 2 4 m Maximum 1 26 mm minimum clearance to combustibles Figure 24C Another method where the vent is not adjacent toawall isillustratedinFigure24D Here sup portstraps 96K93 andsupportplates 96K9...

Page 20: ...htheterminationdownuntilitfullyengages thentwisttheterminationclockwiserunningthe dimples down and along the incline channels until they seat at the end of the channels I Install the roof flashing Ext...

Page 21: ...1 Top Vent TWO 90 DEGREE ELBOWS 40 feet 12 2 meters Maximum uCeiling Firestop Spacer SV4 5VF uWhenusingSecureFlex use Firestop Spacer SF4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4...

Page 22: ...Firestop Spacer SF4 5VF vWhen using Secure Flex use Firestop Spacer SF4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF Table D H H1 Maximum V Mini...

Page 23: ...ccurintheceilingorroofjoists Allowforelbows as indicated in Figure 25 on Page 19 Maintain a minimum 1 26 mm clearance to combustiblesontheverticalsections Clearances for the horizontal runs are 3 77 m...

Page 24: ...articular range of wall thicknesses L Install Firestop Spacer at exterior wall When using the square termination install SV4 5HF Secure Vent SF4 5HF Secure Flex Firestop Spacer over the opening at the...

Page 25: ...ratios that are smaller are acceptable all the way down to at or near level NOTE SV4 5VF SecureVent SF4 5VF SecureFlex firestop spacermust be used anytime vent pipe passes through a combustible floor...

Page 26: ...quired ThisTableshowsa1 V to5 H ratio Forevery1 foot of V vertical you are allowed 5 feet of H H1 horizontal run up to a maximum horizontal run of 20 feet Table H H H1 Maximum V Minimum feet meter fee...

Page 27: ...H1 V1 v Wall Firestop Spacer SV4 5HF uCeiling Firestop Spacer SV4 5VF uCeiling Firestop Spacer SV4 5VF vWall Firestop Spacer SV4 5HF vWall Firestop Spacer SV4 5HF Figure 41 Side Vent THREE 90 DEGREE E...

Page 28: ...he way 2 ApplyabeadofMill PacBlack 700 F high temperature sealant Catalog No 10K81 to the inner adaptor collar approximately 1 2 from the end 3 Pull and extend the inner flexible vent pipe 4 Slidethei...

Page 29: ...cancauseimproperanddangerous operation ATTENTION Aumomentdel entretien descommandes tiqueteztouslesfils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonc tionnement inad quat et...

Page 30: ...is recommended in the gas piping within the home to prevent moisture and debris in the line from damaging the valve These appliances are equipped with a gas flex lineforuse wherepermitted inconnectin...

Page 31: ...y so that none of the wires become loose or disconnected Step 7 VERIFYING APPLIANCE OPERA TION MILLIVOLT Thermocouple Hood Igniter Rod 3 8 Min 9 mm Thermopile Pilot Nozzels Figure 50 Figure 51 Piezo I...

Page 32: ...shutter gap should be increased If air shutter is open too far Flame will be blue Air shutter gap should be decreased Sooting is caused by incomplete combustion in the flames and lack of combustion ai...

Page 33: ...e 53 2 Light appliance follow lighting procedure on lighting label in control compartment or see the Installation and Operation Manual 3 Allow the burner to operate for at least 15 minutes while obser...

Page 34: ...his Area Must Remain Clear of Combustible Materials 3 77 mm Top Spacers Header Step 11 INSTALL FRONT FACE Install front face assembly with barrier Step 12 HOOD INSTALLATION Refer to Figure 55 All of t...

Page 35: ...e fonctionnement du foyer en le faisant basculerdeMarche Arr t etvice versa Nettoyez soigneusement la plaque murale de l interrupteur ou le thermostat mural pour liminer la poussi re etlestracesdegrai...

Page 36: ...ure Vent Components Cat No Model Description H1968 SV4 5HT 2 HorizontalSquareTermina tion With Firestop spacer H2246 Adaptor 74L61 H2152 SV4 5CGV 1 Vertical Termination Cap High Wind Vent Sections Rig...

Page 37: ...52M H2248 SF4 5HF 10 Firestop Spacer Hori zontal flex 3 1 1spacing 10 Pack H2249 SF4 5VF 10 Firestop Spacer Vertical flex 1 1 1 spacing 10 Pk 56L74 SFVT30 Vertical Termination for flex flat to 6 12 wi...

Page 38: ...ly so that none of the wires become loose or disconnected d Locate the two 2 latches at the top of the control compartment To disengage the two latches from the bottom vee flange of the glass enclosur...

Page 39: ...for natural and propane models Figure 59 illustrates the orifice Always check and verify correct orifice size B Install the burner as shown in Figure 60 Ensure that the arm of the venturi of the burn...

Page 40: ...ter des br luresouqueleursv tements ne s enflamment WARNING Clothing or other flammable material should not be placed on or near the appliance AVERTISSEMENT On ne devrait pas placer de v tements ni d...

Page 41: ...y to the left away from the fireplace Refer to Figure 62 for access to the gas control valve Millivolt appliances will be fitted with the gas control valve shown in Figure 62 Familiarize yourself with...

Page 42: ...menea encendi ndola y apag ndola Limpiebienlaplacadelinterruptoro eltermostatodeparedparaquitarelpolvoyaceite Pegue la etiqueta en la superficie de la placa del interruptor que controla la chimenea Fi...

Page 43: ...aware of shrubs and plantings that may encroach on the termination The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techn...

Page 44: ...oors certified with the appliance shall be used Seules des portes certifi es pour cet appareil doivent tre utilis es These are direct vent appliances They are designed to operate only when the front g...

Page 45: ...Figure 65 Do not use more than is necessary Ensure that the main burner ports remain uncovered by the ember material 5 Place Volcanic Stone Spread volcanic stone evenly over firebox floor 6 Install Ve...

Page 46: ...ard Against The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of...

Page 47: ...1 3 Figure 67 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face The Front Position Th...

Page 48: ...shutter opening will need to be An appliance operated with the air shutter opened too far may have flames that appear blue and transparent These weak blue and transparent flames are termed anemic Prop...

Page 49: ...parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The inst...

Page 50: ...wall mounted or placed in the valve compartment Wall Thermostat Wall surface mounted Thermostat or manual ON OFF operation Large LCD screen to display room and set temperature in F and C Connects to...

Page 51: ...er Kits Cat No Model No Description H0778 EBLK PF MHD40PF H0779 EBLK ST MHD40ST OFF ON Wall Switch Kit TheOFF ONwallswitchkitmaybeusedtocontrolthe operation of the fireplace burner Install the OFF ON...

Page 52: ...used by long lateral runs too many elbows and or exterior portions of the systembeingexposedtocoldweather Alsoinspectwallstraps or plumbers s tape to ensure it is secure and in place Appliance Checkou...

Page 53: ...immediately call your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE If the pilot will not stay lit after several tries turn the gas control knob to OFF and call...

Page 54: ...imm diatement un technicien qualifi ou le fournisseur de gaz Si la veilleuse ne reste pas allum e apr s plusieurs tentatives r glez la manette d admission du gaz la position OFF et appelez un technic...

Page 55: ...shooting should only be accomplished by a qualified service technician Clean and or adjust pilot flame for maximum flame impinge ment on thermocouple Figure 50 on Page 31 Check burner orifice for stop...

Page 56: ...Face Assembly with Barrier J7531 0 1 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in proper...

Page 57: ...or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c damage...

Page 58: ...Date fireplace was Installed Type of gas fireplace uses Dealer name Innovative Hearth Products reserves the right to make changes at any time without notice in design materials specifications prices a...

Reviews: