External Signal Exchange
92/121
Operating Manual dryve D1, ST-, DC-, EC/BLDC-Motor Control System - V2.4
6.4.17 Detailed description of the objects for motion control
6040h Controlword
Short description
Object for controlling the dryve D1
Parameter Name
Control Word
Object Type
VAR
0x7
Date Type
UNSIGNED16
0x0006
Access
RWW
PDO Mapping
Yes
Bit Assignment
0
Switch On
1
Enable Voltage
2
Quick Stop
3
Enable Operation
4
Mode Specific
5
Mode Specific
6
Mode Specific
7
Fault Reset
8
Stop
9
Mode Specific
10
Reserved
11
Manufacturer Specific
12
Manufacturer Specific
13
Manufacturer Specific
14
Manufacturer Specific
15
Manufacturer Specific
Example write “Controlword” – Command “Shutdown”
CANopen
COB-ID
DLC
Byte0
Byte1
Byte2
Byte3
Byte4
Byte5
Byte6
Byte7
601h
8h
2Bh
40h
60h
00h
6h
00h
00h
00h
Modbus TCP as Gateway
6041h Statusword
Short description
Feedback of status information of the dryve D1
Parameter Name
Status Word
Object Type
VAR
0x7
Date Type
UNSIGNED16
0x0006
Access
RO
PDO Mapping
Yes
Bit Assignment
0
Ready to Switch On
1
Switched On
2
Operation Enabled
3
Fault
4
Voltage Enable
5
Quick Stop
6
Switch On Disabled
7
Warning
8
Manufacturer Specific
9
Remote
10 Target Reached
11 Internal Limit Active
12 Mode Specific
13 Mode Specific
14 Manufacturer Specific
15 Manufacturer Specific
Byte
0 - 4
5
6
7
8
9
10 - 11
12
13
14 - 17
18
19
20 - 22
bin
0000 0000
0000 1110 0000 0000
0010 1011 0000 1101 0000 0001
0000 0000
0110 0000
0100 0000
0000 0000
0000 0001
0000 0110
not send
hex 0h
0Eh
0h
2Bh
0Dh
1h
0h
60h
40h
0h
1h
6h
not send
dec 0
14
0
43
13
1
0
96
64
0
1
6
not send