The device does not reach the proper temperature, the lighting is on...– Make sure that:
• The main switch is on
• Temperature setting on the thermostat is properly set
• Thermostat works properly
• The condenser is clean, if necessary – clean the condenser
• Ambient temperature does not exceed 25ºC
• Enough time has passed for products to be cooled
• Ventilation holes of the device are not blocked
(This concerns the “IGLOO” thermostat) thermostat displays C0 or C1 or C2 instead of displaying temperature:
This situation shall occur, when one of temperature regulation sensors has been destroyed.
The following messages may be displayed in such case:
• C0 – temperature sensors inside the chamber are damaged – call authorized service
• C1 – failure of evaporator sensor - call authorized service
• C2 – failure of condenser alarm sensors (or failure of second evaporator sensor) – call authorized service
(This concerns the “CAREL” thermostat) Thermostat displays E0 or E1 or L0 or HI or EE or Ed or DF instead
of temperature:
• E0 – failure of temperature sensor inside the chamber – call authorized service
• E1 – failure of evaporator sensor – call authorized service
• L0 – low temperature alarm (lower than temperature range set within the device – call authorized service
• HI – high temperature alarm – call authorized service
• EE – internal defect of the regulator – call authorized service
• Ed – max. defrosting time exceeded
• DF – defrosting in progress (this is not an alarm signal)
(This concerns the “IGLOO” thermostat) The device is working, sound signalling is activated...– Make sure that:
• The condenser is clean, if necessary – clean the condenser
• Condenser ventilator is working properly
• Ambient temperature does not exceed 25ºC
The device is working too loud...– Make sure that:
• The device is standing stably
• Furniture adjoining the device do not vibrate when the cooling aggregate compressor is working
Noises made by the operating device are a normal phenomenon. The devices are equipped with venti-
lators, engines and compressors, which turn on and off automatically. Each compressor makes certain noises
when operating. These sounds are made by the aggregate engine and by cooling agent
fl
owing through the cir-
cuit. This phenomenon constitutes a technical feature of cooling devices and it does not signify their faulty work.
Steam precipitation on glasses of the device is a normal phenomenon in case of high relative air
humidity exceeding 60% and does not require calling the service!
• Serial number (NS)
• Production date
• Type (name of the device)
and
• Date when the device was
purchased
• Description of the problem
• Your exact address and telephone
number (with the code number)
Fig.12 Data plate
6.2. Service
IGLOO service telephone number:
+48 (14) 662 19 56 or +48 605 606 071
e-mail: [email protected]
If after checking points described in chapter
6.1 “Fault identi
fi
cation and repair” the
device still does not work properly, please
contact Technical Service of the Igloo
company, stating the data from the data
plate Fig.12 (p.18):
The above
fi
gure shows a demon-
strative data plate and the data stated
on the plate are exemplary data,
which are not related with “Monika 2,
Rota” device!
The data plate is located at the back
of the device, in the upper right cor-
ner, below the top Fig.1/18 (p.12)