Installation
& Operation
Dimension
Name
Minimum
Maximum for
Terminal
Maximum for XLR
(In-Line)
A
Remove Cable Jacket
1" (25.4mm)
2-1/4" (60mm)
1-1/4" (31.8mm)
B
Drain Wire Heatshrink
Dim 'A' - 1/8" (3.2mm)
-
-
To terminate shielded cable:
1. Strip off specified length of outer jacket.
2. Cut shield (foil or braid) flush to outer
jacket. DO NOT cut drain wire.
3. Fit specified length of 1/16" heatshrink
tubing over the drain wire.
4. For solder connections, fit a 1/2" length of
1/16" heatshrink tubing over each conduc-
tor.
5. Fit a 1" length of 3/8" heatshrink tubing
over the entire cable. Position it so that
3/4" of its length is over the cable jacket-
ing, and 1/4" of its length is over the loose
conductors.
6. Strip 1/8" inch of the insulation from each
of the conductors.
7. Terminate the conductors on the terminal
block, or solder the terminals as specified.
8. For solder connections, shrink the individ-
ual 1/2" lengths of heatshrink tubing over
the solder terminals.
9. Shrink the remaining heatshrink tubing.
10.Apply the appropriate ID label to the cable
at the end of the outer heatshrink tubing.
T
ERMINATION OF
E
THERNET
C
ABLE
Function
PAIR #
PIN OUT (T568B)
Wire Color
(T1)
(R1)
1
5
4
White w/ Blue
Blue
Tx + (T2)
Tx - (R2)
2
1
2
White w/ Orange
Orange
Rx + (T3)
Rx - (R3)
3
3
6
White w/ Green
Green
(T4)
(R4)
4
7
8
White w/ Brown
Brown
To terminate Ethernet cable:
1. Strip off outer jacket - approximately 1-1/2" (37.6mm)
2. Fit a piece of 1-1/8" (28.6mm) long heatshrink tubing over the cable extending out 1/4" (8.25mm) from outer jacket.
3. Terminate approximately 1/2" (12.2mm) from end of conductors on Type 110 punch down block or connector per schedule (T568B)
- Maximum untwist of conductors to terminations is 1/2" (12.2mm)
- Trim excess leads.
4. Shrink tubing and add appropriate ID label to the cable at the end of the heatshrink tubing.
System topology and labeling should follow TIA/EIA-568 and TIA/EIA-606 as applicable and guidelines in ESTA's
Recommended
Practice For Ethernet Cabling Systems in Entertainment Lighting Applications
and Supplement.
Per TIA/EIA-568, Maximum length of any horizontal cable run (i.e. between Ethernet RJ-45 receptacle (work area) and Patch Panel) is
90 meters; Maximum length of any CATEGORY 5 cables at the Ethernet RJ-45 receptacle (work area) is 3 meters.
Ethernet equipment (e.g. Patch Panels, Hubs or Switches) should be maintained in an environment of 18°-24° C (64° - 75° F) and 30%
- 55% relative humidity per TIA/EIA-569-A.
Maximum length of any segment (cable run - including device cables - between Hub or Switch and Node) is 90 meters. Maximum
network diameter (distance between any two Nodes) is 180 meters.
Cable Type
(10/100 Base-T Ethernet)
Description
Belden #1583A or equal
- Nominal O.D. 0.214" (5.54mm)
CATEGORY 5: Non-Plenum Rated
4-Unshielded Twisted Pairs (UTP) #24AWG
Belden #1585A or equal
- Nominal O.D. 0.206" (5.23mm)
CATEGORY 5: Plenum Rated
4-Unshielded Twisted Pairs (UTP) #24AWG
Appendix A: Standard Wiring (continued)
Contractor is Responsible for All CAT5e Terminations