35
UK
12.2.4 Safety light curtains: 90 mm resolution
OY104S
OY105S
OY106S
OY107S
OY108S
OY109S
OY1
10S
Total length L
[mm]
663
813
963
1113
1263
1413
1563
Protected area height [mm]
610
760
910
1060
1210
1360
1510
Response time
[ms]
4
4,5
5
5,5
5,5
6
6,5
Safety-related reliability
PFH
D
[1/h] 7,8
-09
8,3
-09
8,8
-09
9,3
-09
9,8
-09
1,0
-08
1,1
-08
Test pulse duration t
i
[µs]
80
80
80
80
80
80
80
Test pulse interval T [ms]
4,0
4,4
4,8
5,3
5,7
6,2
6,6
Ratio t
i
/ T
[%]
2,0
1,8
1,7
1,5
1,4
1,3
1,2
12.2.5 Safety light grids 2, 3 and 4 beams
OY114S
OY115S
OY116S
Number of beams
2
3
4
Total length L
[mm]
653
953
1053
Protected area height [mm]
510
810
910
Response time
[ms]
2,5
3
3
Safety-related reliability
PFH
D
[1/h]
6,9
-09
7,6
-09
8,2
-09
Test pulse duration t
i
[µs]
80
80
80
Test pulse interval T [ms]
2,6
2,9
3,1
Ratio t
i
/ T
[%]
3,1
2,8
2,6
13 Troubleshooting
The LEDs of the transmitter and the receiver indicate faulty operating states
Operating and display elements). For a detailed fault description see the following
tables.