OGD25x OGD55x
Photoelectric distance sensor
34
u
Select [Sequence modulation] .
u
Set one of the options.
11.3.6 Setting the display
2 settings can be selected:
•
[On] = the measured value display is activated in the Run mode.
•
[OFF] = the measured value display is deactivated in the Run mode. When one button is pressed,
the current measured value is displayed for 30 s.
The status LEDs and the PWR status LED remain active even when the display is switched off.
11.3.6.1 Parameter setting via the device keys
u
Change to [EF].
u
Use [▲/▼] to select the parameter [diS.b].
u
Confirm by clicking on [●].
w
Set parameter value is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.
u
Set the parameter value using [▲/▼].
u
Confirm by clicking on [●].
w
The setting is confirmed.
11.3.6.2 Parameter setting via IO-Link
u
Call up [Parameter] > [Setting of the sensor display].
u
Select [diS.B].
u
Set one of the options.
11.3.7 Setting the display colours
Set the display colour for the measured values in Run mode.
The following colour settings are available:
•
[G-12]: green display colour when [OUx] switches.
•
[r-12]: red display colour when [OUx] switches.
•
[Gxou]: green display colour when [OUx] switches.
•
[rxou]: red display colour when [OUx] switches.
•
[GrEn]: green display colour.
•
[rEd]: red display colour.
11.3.7.1 Parameter setting via the device keys
u
Change to [EF].
u
Use [▲/▼] to select the parameter [coLr].
u
Confirm by clicking on [●].
w
Set parameter value is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.