OGD25x OGD55x
Photoelectric distance sensor
26
11.1.3.1 Parameter setting via the device keys
Locking
Make sure that the device is in the normal operating mode.
u
Keep [▲] + [▼] pressed (approx. 10 s) until [Lo] is displayed.
w
The device is locked.
[Lo] is displayed briefly if you try to change parameter values on the locked device during
operation.
Unlocking
u
Keep [▲] + [▼] pressed (approx. 10 s) until [uLo] is displayed.
w
The device is unlocked.
11.1.3.2 Parameter setting via IO-Link
u
Call up [Parameters] > [Display settings].
u
Select [Loc].
u
Set [Loc] for locking and [uLoc] for unlocking.
11.2 Configuring the basic settings
11.2.1 Output configuration
The following output configurations for the outputs [OU1] / [OU2] can be set:
•
[I]*: Analogue output for current.
•
[U]
*
: Analogue output for voltage.
•
[Hno]: Hysteresis function, normally open.
•
[Hnc]: Hysteresis function, normally closed.
•
[Fno]: Window function, normally open.
•
[Fnc]: Window function, normally closed.
•
[OFF]: Output off.
*) Only selectable for analogue devices under [OU2].
11.2.1.1 Parameter setting via the device keys
u
Change to menu level 1.
u
Select [OU1] / [OU2].
u
Confirm by clicking on [●].
w
The set output configuration is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.
u
Use [▲/▼] to select the output configuration [I]*, [U]*, [Hno], [Hnc], [Fno] or [Fnc].
u
Confirm by clicking on [●].
u
The setting is confirmed.
*) Only selectable for analogue devices under [OU2].