Photoelectric distance sensor
OGD25x OGD55x
31
•
[Fast]: is optimised with regard to measuring speed (“measuring rate / switching rate") and
addresses highly dynamic applications. The max. range with dark objects is lower than with “Fine”
and “Standard”.
Operating mode
Velocity
Repeatability
Max. range (black)
[Fine]
+
+++
+++
[Standard]
++
++
+++
[Fast]
+++
+
+
The table provides a preliminary assessment of different applications and the respective
operating modes. The rating scale ranges from “+” (less suitable) to “+++” (very suitable).
11.3.1.1 Parameter setting via the device keys
u
Change to [EF].
u
Use [▲/▼] to select the parameter [OPEr].
u
Confirm by clicking on [●].
w
Set parameter value is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.
u
Set the parameter value using [▲/▼].
u
Confirm by clicking on [●].
w
The setting is confirmed.
11.3.1.2 Parameter setting via IO-Link
u
Call up [Parameter] > [Basic settings].
u
Select [OPEr].
u
Set one of the options.
11.3.2 Setting the delay time for switching outputs
2 delay times can be selected:
•
[dS1 / dS2] = switch-on delay
•
[dr1 / dr2] = switch-off delay
Setting range [s]: 0...5 s in steps of 0.01 s
(0 = delay time is not active)
[dS1 / dr1] is the switch-on and switch-off delay for [OU1].
[dS2 / dr2] is the switch-on and switch-off delay for [OU2].
11.3.2.1 Parameter setting via the device keys
u
Change to [EF].
u
Use [▲/▼] to select the parameter:
[dS1 / dS2] = switch-on delay
[dr1 / dr2] = switch-off delay
u
Confirm by clicking on [●].
w
Set parameter value is displayed.
u
Keep [▲] or [▼] pressed for at least 3 s.
u
Use [▲/▼] to set the parameters [dS1 / dS2] or [dr1 / dr2].