background image

5

UK

7.3 Setting of the maximum sensitivity

 

Align the sensor so that no light is reflected.

The sensor is to switch when the object is detected

 

First press [OUT on], then [OUT off].

The sensor is to switch when the object is not detected

 

First press [OUT off], then [OUT on].

7.4 Programming unsuccessful

 

> The LED flashes quickly, 8 Hz.
•  Measured value difference too small.
•  Max. programming time of 15 min. exceeded.

7.5 Electronic lock

Lock or unlock the buttons

 

Press [OUT on] and [OUT off] simultaneously for 10 s.

 

> Acknowledgement is indicated by a change of the LED status.

8 Operation

 

Check whether the unit operates correctly.

 

> The LED lights when the switching output is switched.

9 Maintenance, repair and disposal

 

Keep the front pane of the sensor free from soiling.

 

For cleaning do not use any solvents or cleaning agents which could damage 

the plastic material.

 

Do not try to open the module enclosure. There are no user - serviceable 

components inside.

Technical data and further information at www.ifm.com

Summary of Contents for O5P7 Series

Page 1: ...Operating instructions Retro reflective sensor O5P7xx 80284273 00 04 2019 UK ...

Page 2: ...ed herein may result in hazardous radiation exposure Visible laser light CLASS 1 LASER PRODUCT EN IEC 60825 1 2007 and EN IEC 60825 1 2014 complies with 21 CFR 1040 except for deviations pursuant to Laser Notice No 50 dated June 2007 Position of the product label Additional label 3 Functions and features In conjunction with a prismatic reflector or reflective tape the retro reflective sensor detec...

Page 3: ...ure it to a bracket Maximum range is only possible with precise alignment 5 Operating and display elements 1 LED 2 OUT on 3 OUT off 6 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installation of electrical equipment must be adhered to Voltage supply according to EN 50178 ...

Page 4: ...or 2 s The sensitivity is set to the object The yellow LED flashes 2 Remove the object Press OUT off The sensitivity is set without object The yellow LED goes out The programming is finished 7 2 The sensor is not to switch when the object is detected Position the object see figure 1 and press OUT off Remove the object see figure 2 and press OUT on The setting can also be carried out first without ...

Page 5: ...ceeded 7 5 Electronic lock Lock or unlock the buttons Press OUT on and OUT off simultaneously for 10 s Acknowledgement is indicated by a change of the LED status 8 Operation Check whether the unit operates correctly The LED lights when the switching output is switched 9 Maintenance repair and disposal Keep the front pane of the sensor free from soiling For cleaning do not use any solvents or clean...

Reviews: