4
►
Disconnect power.
►
Connect the unit as follows:
DC PNP
pin 1 = L+ (10...36 V DC)
(pin 2 = not connected)
pin 3 = L-
pin 4 = load (PNP, 200 mA)
7 Settings
7.1 The sensor is to switch when the object is detected
1
►
Position the object.
►
Press [OUT on] for 2 s.
> The sensitivity is set to the object.
> The yellow LED flashes.
2
►
Remove the object.
►
Press [OUT off].
> The sensitivity is set without object.
> The yellow LED goes out. The programming is finished.
7.2 The sensor is not to switch when the object is detected
►
Position the object (see figure 1) and press [OUT off].
►
Remove the object (see figure 2) and press [OUT on].
The setting can also be carried out first without object and then with object.