10
4.2.2 Voltage output
Factory setting
Measuring range scaled
9795,5 (AEP)
0
MEW
ASP
AEP
0 (ASP)
MEW= final value of the measuring range
In the set measuring range the output signal is between 0 and 10 V�
4.3 Switch off the laser
For safety and maintenance purposes the laser of the unit can be temporarily
switched off via the input on pin 5�
Input signal at pin 5
Laser
Low / not connected
On
High
Off
4.4 IO-Link
This unit has an IO-Link communication interface which enables direct access
to process and diagnostic data� In addition it is possible to set the parameters of
the unit during operation� Operation of the unit via IO-Link interface requires an
IO-Link master�
With a PC, suitable IO-Link software and an IO-Link adapter cable communication
is possible when the system is not in operation�
The IODDs necessary for the configuration of the unit, detailed information about
process data structure, diagnostic information, parameter addresses and the
necessary information about the required IO-Link hardware and software can be
found at www�ifm�com�