6.2.2 Installation in the active zone
The minimum distance (a2) has to be observed between the maximum
level (b2) and the mounting element (Fig. 6.3 and Table 6-4) !
►
Fix mounting elements in the mounting
zone (M) (Fig. 6-1). Adhere to the
maximum permitted outside length (c)
(see Table 6-1 ).
►
Ensure that the maximum level (b2)
is not exceeded after completed
installation:
(b2) = (L) - (c) - (a2)
(without offset).
►
Observe further minimum distances
according to Table 6-4.
Fig. 6-3
c
b2
L
u
a2
x
c:
outside length
(max. outside length Table 6-1)
a2: minimum distance between mounting
element and maximum level (b)
b2: max. level from the lower edge of
the sensor
Table
6-4
MEdI = CLW.1
MEdI = CLW.2, OIL.1
MEdI = OIL.2 / Auto
[cm]
[inch]
[cm]
[inch]
[cm]
[inch]
x
2.0
0.8
3.0
1.2
4.0
1.6
u
1.0
0.4
1.0
0.4
1.0
0.4
a2 (LK8122)
2.0
0.8
2.5
1.0
3.0
1.2
a2 (LK8123)
4.0
1.6
4.5
1.8
5.0
2.0
a2 (LK8124)
6.0
2.4
7.0
2.8
8.0
3.2
v *
)
4.5
1.8
4.5
1.8
4.5
1.8
w *
)
4.0
1.6
5.0
2.0
6.0
2.4
*
)
→ Fig. 6-1.