24
adjustment has been carried out� If no adjustment has been carried out, this is
indicated by means of a periodic running light�
Some or all of the LEDs can be deactivated via IO-Link
�
The following LED modes can be set:
• all LEDs inactive
• only status LED active
• status and switch point LEDs active
•
all LEDs active (factory setting)
10 Parameter setting
10.1 Parameter setting via PC and IO-Link master
►
Prepare P
C, software and master → observe the operating instructions of the
respective units / software�
►
Connect the unit with the IO-Link master�
►
Follow the menu of the IO-Link software�
> Without ifm software: parameter setting according to the IODD PDF�
►
Set the parameters�
►
Check if the parameter setting was accepted by the unit� If necessary, read
sensor again�
►
Put the unit into operation (if necessary,
remove the IO-Link master).
10.2 Adjustable parameters
The following IO-Link parameters merely provide an overview�A complete
list can be found in the IODD of the unit�
10.2.1 Sensor parameters
Parameter
Value range
Description
Sensitivity
High (2)
Low (0)
Sets the unit's sensitivity, two levels
are available�
Orientation
Connector at bottom (0)
Connector on top (1)
Changes the measuring logic of the
unit, depending on installation with the
cable facing upwards or downwards�