![IFM Efector600 TN2531 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/ifm/efector600-tn2531/efector600-tn2531_operating-instructions-manual_3919456006.webp)
6
Current output 4...20 mA
Factory setting
Measuring range scaled
������
������
�
��
���
���
������
�
��
���
���
���
��� ������
In the set measuring range the output signal is between 4 and 20 mA.
The green LED also indicates:
Temperature above the measuring range: Output signal 20...20.5 mA.
•
Temperature below the measuring range: Output signal drops to max. 3.8 mA.
•
If the detection zone is not reached or is exceeded (T < -60°C or T > +160°C), the output
•
behaves according to the parameter set in FOU2 (→ 9.5.3).
Voltage output 0...10 V
Factory setting
measuring range scaled
�����
��
���
���
������
�����
��
���
���
���
��� ������
In the set measuring range the output signal is between 0 and 10V.
The green LED also indicates:
Temperature above the measuring range: Output signal 10...10.3 V.
•
If the detection zone is not reached or is exceeded (T < -60°C or T > +160°C), the output
•
behaves according to the parameter set in FOU2 (→ 9.5.4).