6 Set-up and settings for water
(For media other than water → 7.1: Low flow adjustment).
►
Switch on the supply voltage�
>
All LEDs light and go out again step by step. During this time the output is
closed (if configured as normally open)� The unit is in the operating mode�
►
Let the normal flow circulate in the installation�
►
Check the display and determine further actions�
1
The factory setting is suitable for the applica-
tion�
►
No further settings are required�
2
Your normal flow is below the representation
range of the display�
2 setting options:
► Change the switch point (→ 6.1).
► Carry out high flow adjustment (→ 6.2).
3
Your normal flow exceeds the representation
range of the display (LED 9 flashes).
► Carry out high flow adjustment (→ 6.2).
You can restore the factory setting any time. (→ 7.3).
6.1 Change the switch point (optional)
For the factory setting the switch point is at LED 7. A change makes sense if:
•
the display shows example 2�
•
the flow fluctuates much or pulsates�
• if a faster response time of the unit is requested (low switch point = fast re
-
sponse with rising flow, high switch point = fast response with falling flow).
►
Briefly press the pushbutton
or �
>
The switch point LED flashes.
►
Press the pushbutton
or as often as required� Each press of the push-
button shifts the LED by one position in the indicated direction.
Note: If no pushbutton is pressed for 2 s, the unit returns to the operating mode
with the newly set value�
Summary of Contents for efector300 SI6000
Page 1: ...Operating instructions Flow monitors SI6000 SI6100 SI6200 706053 00 06 2011 UK ...
Page 13: ...13 UK 11 Scale drawing SI6000 1 LED bar display 2 set button 3 Aseptoflex thread ...
Page 14: ...14 SI6100 1 LED bar display 2 set button 3 Aseptoflex thread ...
Page 15: ...15 UK SI6200 1 LED bar display 2 set button 3 Aseptoflex thread ...