Connection of pulse pick-ups
The S 200 provides approx. 24 V DC (max. 30 mA) for the supply of pulse pick-
ups. Pulse pick-ups which need higher voltage/higher current consumption
must have an external supply. In this case the reference point of the external
voltage must be connected to terminal 11; the positive pole of the external
power supply must not be connected with the S 200.
Please also adhere to the SELV criteria for the pulse pick-up connection so that
there is no dangerous contact voltage at the sensor which can enter the unit!
Page 18
1 2 3 4 5 6
BN
BU
BN
BU
BN
BK
BU
BN
BK
BU
1 2 3 4 5 6
1 2 3 4 5 6
1 2 3 4 5 6
WH
BK
WH
BK
3-wire DC PNP
2-wire DC quadronorm
2-wire AC / DC
mechanical switch
Summary of Contents for Ecomat 200 S 200