background image

C

ABINET

C

ONTROLLER

CR0303

9

UK

X10

X11

X20

X21

198

226

133

108

5,8

7,8

X12

P/N1

N2

1

2

ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen

28.01.2015

CR0303

Mobile controller

CabinetController

24 inputs / 18 outputs

2nd CAN interface

for gateway function

according to SAE J 1939

Programming

to IEC 61131-3

10...32 V DC

We reserve the right to make technical alterations without prior notice!

CR0303 / page 1

Technial data

Usable as CANopen master or intelligent I/O module

Housing

plastic housing (black)

with transparent hinged cover for operating elements and indicators

Dimensions (L x W x H)

226 x 133 x 39 mm

Mounting

fixation via 4 screws M 4 to DIN 912 or DIN 7984

and 4 tubular rivets to DIN 7340 (tubular rivets are enclosed)

Connections

AMP crimp connector, to be clipped into place and thus vibration-resistant, protected against reverse polarity

(AMP junior timer contacts)

inputs/outputs

2 x 10-pole, 3 x 18-pole

operating voltage, CAN bus

1 x 6-pole

programming, TEST

1 x 6-pole

Weight

0.68 kg

Operation/storage temperature

– 40...85 °C

Protection rating 

IP 20

Inputs

24

Possible configurations

Outputs

18

Possible configurations

Operating voltage U

B

10...32 V DC

Nominal voltage

12/24 V DC

overvoltage

36 V for t

10 s

undervoltage detection

for U

B

9.5 V

auto save

for U

B

9.0 V

Current consumption

≤ 

100 mA (without external load 24 V DC)

Quantity

Signal

Description

8

digital 

for positive sensor signals, with diagnostic capability

B

L

4

digital

for positive sensor signals, with diagnostic capability

B

L

or

frequency

pulse inputs, max. 30 kHz

I

L

4

digital

for positive/negative sensor signals, 

B

L/H

8

analogue

0...10/32 V DC, 0...20 mA or ratiometric

A

or

digital

as binary voltage input

B

L

Quantity

Signal

Description

8

digital

positive switching (high side)

B

H

or

PWM

PWM frequency max. 250 Hz

PWM

4

digital

positive switching (high side), 4 A

B

H

digital

positive switching (high side), 10 A

B

H

1) LED   2) rotary switch

Summary of Contents for Ecomat 100 CR0303

Page 1: ...Device manual Mobile controller CabinetController CR0303 UK 7390608 01 03 2015...

Page 2: ...quency inputs page 7 5 Setup 5 1 Programming page 8 6 Technical data data sheets 1 5 Dimensions mechanics electronics page 9 Operating and indicating elements page 10 Rotary switch coding page 10 Oper...

Page 3: ...ELV circuit of the device must al so comply with the SELV criteria safety extra low voltage safe electrical separa tion from other electric circuits If the supplied SELV voltage has an external connec...

Page 4: ...master or intelligent I O module The user is responsible for the safe function of the application programs which he created himself If necessary he must additionally carry out an ap proval test by cor...

Page 5: ...Nm Mounting position any Hole dimensions see back of the controller or Technical data page 9 3 3 Cooling As the internal heating of the electronics is conducted away via the housing en sure sufficien...

Page 6: ...er the individual electric circuits must be protected www ifm com CABINETCONTROLLER CR0303 6 Designation Potential Plug pin Fuse Supply voltage module VBBS P N1 01 max 2 A T Supply voltage OUT00 03 VB...

Page 7: ...ns and machinery 4 4 Frequency inputs Operate frequency inputs with screened cables so that useful signals are not affected by external interference CABINETCONTROLLER CR0303 7 UK sensor sensor load su...

Page 8: ...manual CoDeSys V2 3 alternatively online help CoDeSys If the system manual R360 is not available please contact one of the ifm branch offices overleaf for your free copy System manual R360 English or...

Page 9: ...junior timer contacts inputs outputs 2 x 10 pole 3 x 18 pole operating voltage CAN bus 1 x 6 pole programming TEST 1 x 6 pole Weight 0 68 kg Operation storage temperature 40 85 C Protection rating IP...

Page 10: ...n protocol predefined ifm protocol INTELHEX or free protocol Controller CMOS microcontroller 16 bits C167C 40 MHz Memory program memory 576 Kbytes flash data memory 80 Kbytes SRAM 32 Kbytes flash 2 Kb...

Page 11: ...50 Hz Digital inputs for negative sensor signals switch on level 0 2 UB switch off level 0 5 UB input resistance 3 17 k input frequency 50 Hz Analogue inputs A Voltage inputs X11 01 04 07 10 input vo...

Page 12: ...utput for the sensor supply X20 14 voltage 5 10 V DC can be selected switched off or read back The 10 V output requires at least 13 V supply voltage to work current 400 mA accuracy 5 Note free wheelin...

Page 13: ...A 01 A_IN16 A A A A A A 06 05 04 03 02 01 CAN2_H CAN2_L CAN1_H CAN1_L GND VBBS P N1 Power supply CAN Bus 06 05 04 03 02 01 n c TEST RS 232 TxD RS 232 RxD GND VBBTEST N2 RS 232 Test X21 Outputs 14 13...

Page 14: ...only be carried out by the manufacturer The disposal must be carried out according to the corresponding national envi ronmental regulations 8 Approvals standards For test standards and regulations se...