C
ABINET
C
ONTROLLER
CR0303
12
CR0303
Characteristics of the outputs
Digital outputs
(B
H
, PWM)
■
Solid state outputs, positive switching (high side), short-circuit and overload protected
X21:01...04, 06...09
switching voltage
10...32 V DC
OUT 00...OUT 07
switching current
max. 4 A
total current
max. 12 A
■
PWM outputs
PWM frequency
max. 250 Hz
setting resolution
0.1 %
switching current
max. 4 A
OUT 00...03 are combined with a common VBB
O
connection.
OUT 04...07 are combined with a common VBB
O
connection.
Digital outputs
(B
H
)
■
Solid state outputs, positive switching (high side), short-circuit and overload protected
X20:15...18
switching voltage
10...32 V DC
OUT 08...OUT 11
switching current
max. 4 A
total current
max. 12 A
OUT 08...11 are combined with a common VBB
O
connection.
Digital outputs
(B
H
)
■
Solid state outputs, positive switching (high side), short-circuit and overload protected
X20:02, 04, 06, 08, 10, 12
switching voltage
10...32 V DC
OUT 12...OUT 17 (10 A)
switching current
max. 10 A
total current
max. 30 A
Value ranges for diagnosis and switch-off
Warning
10...16.5 A (typ. 12 A)
Error (switch-off)
13...21.5 A (typ. 16 A)
OUT 12...OUT 17 each have a power supply connection VBB
O
Voltage output
(VBB
STAB 5/10 V
)
■
Voltage output for the sensor supply
X20:14
voltage
5/10 V DC (can be selected, switched off or read back)
The 10 V output requires at least 13 V supply voltage to work.
current
400 mA
accuracy
± 5 %
Note
free-wheeling diode for the connection of inductive loads is integrated
Overload protection
max. 5 minutes (in case of 100 % overload)
(valid for all outputs)
Short-circuit stability
max. 5 minutes cVBB with GND
(valid for all inputs/outputs)
wiring see page 5
Test standards and regulations
Climatic test
damp heat to EN 60068-2-30, test Db
(
≤
95 % rel. air humidity, non-condensing)
protection test to EN 60529
Mechanical resistance
vibration to EN 60068-2-6, test Fc
shock to EN 60068-2-27, test Ea
bump to EN 60068-2-29, test Eb
Immunity to
to ISO 7637-2, pulses 2, 3a, 3b, severity level 4, function state A
conducted interference
to ISO 7637-2, pulse 5, severity level 1, function state A
to ISO 7637-2, pulse 1, severity level 4, function state C
Immunity to interfering fields
according to UN/ECE-R10 at 100 V/m (E1 type approval)
and DIN EN 61326 (CE)
Interference emission
according to UN/ECE-R10 (E1 type approval)
and DIN EN 61326 (CE)
Tests for the approval for railway applications
to BN 411 002 (DIN EN 50155 point 10.2 and DIN EN 50121)