1  Preliminary note

This document is intended for specialists� These specialists are people who are 

qualified by their appropriate training and their experience to see risks and to 

avoid possible hazards that may be caused during operation or maintenance of 

the accessories� The document contains information about the correct handling of 

the accessories�
Read this document before use to familiarise yourself with operating conditions 

and installation� Keep this document during the entire duration of use of the 

accessories�

1.1  Symbols used

Instruction

>

Reaction, result

[…] Designation of keys, buttons or indications

Cross-reference

Important note 

Non-compliance may result in malfunction or interference�

Information 

Supplementary note

2  Functions and features

The units of design O3D3xx are installed directly behind a pane as protection 

against weather conditions� To ensure that the units operate without any 

restrictions behind a pane, one of the light seals E3D306 and E3D307 has to 

be used� The light seals prevent scattered light and thus impaired measurement 

accuracy� 
The E3D306 light seal is self-adhesive and is directly applied to the O3D3xx�
The E3D307 light seal is not self-adhesive and is inserted in a corresponding 

groove in the pane�

Summary of Contents for E3D306

Page 1: ...Installation instructions Light seal E3D306 E3D307 80286819 00 07 2019 UK ...

Page 2: ...2 Contents 1 Preliminary note 3 1 1 Symbols used 3 2 Functions and features 3 3 Items supplied 4 3 1 E3D306 4 3 2 E3D307 4 4 Installation 4 4 1 Install E3D306 4 4 2 Install E3D307 6 ...

Page 3: ...ries 1 1 Symbols used Instruction Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note 2 Functions and features The units of design O3D3xx are installed directly behind a pane as protection against weather conditions To ensure that the units operate without any restrictions ...

Page 4: ... not self adhesive Installation instructions 4 Installation 4 1 Install E3D306 The E3D306 light seal is self adhesive and is directly applied to the O3D3xx The light seal must not be compressed during installation The light seal can lead to impaired measurement accuracy in the top and bottom image zones ...

Page 5: ...t touch the adhesive side of the light seal 3 Attach the light seal as shown in Fig 1 The 4 recesses of the light seal must be positioned exactly on the corners highlighted in Fig 1 4 Install the O3D3xx with the light seal behind a pane The maximum thickness of the pane is 1 mm Thicker panes lead to impaired measurement accuracy of the O3D3xx Installation of the O3D3xx is described in the quick re...

Page 6: ...nstallation of the light seal the pane has to be milled Install the light seal 1 Mill the pane It must be possible to insert the light seal shown in Fig 2 in the pane Fig 2 E3D307 scale drawing The pane must be T1 4 mm thick The milling must be T2 3 3 mm deep Fig 3 milled pane for E3D307 2 Insert the light seal in the milled pane ...

Page 7: ... 4 E3D307 inserted in pane with installed O3D3xx 3 Align the lens of the O3D3xx centred to the light seal As shown in Fig 4 the light seal must be positioned exactly on the metal stiffeners between lens and illumination unit 4 Install the O3D3xx behind the pane Installation of the O3D3xx is described in the quick reference guide of the O3D3xx The light seal is installed ...

Reviews: