5

E2M231 / E2M232 monitor for analogue cameras

UK

3  Functions and features

The E2M231 / E2M232 monitor processes input signals from analogue cameras and shows them on the 

internal display . The parameters of the device are set via integrated keys . The device is available in 2 

versions:

 

with 1 analogue video input (E2M231) 

 

with 2 analogue video inputs (E2M232)

The O2M2xx and O3M2xx cameras from ifm electronic are compatible with the device .
The device must not be operated during safety-critical operations .
Because of the requirements for electromagnetic interference emissions, the device is intended for use in 

industrial environments . The device is not designed for use in domestic areas .

The device may only be used under the operating conditions specified in the data sheet . 

4  Function keys

The following keys are on the front of the device:

 

n

i  

n

i

 

s

t

c

e

j

b

o

 

s

t

c

e

j

b

o

 

e

r

a  

e

r

a

 r

o

ti

n

o

m

 r

o

ti

n

o

m

 r

e

s

o

l

c

 r

e

s

o

l

c

 

n

a

h

t

 

n

a

h

t

r

a

e

p

p

a

r

a

e

p

p

a

 

y

e

h

t

 

y

e

h

t

Symbol

Name

Function

Camera switch

Select between the connected cameras . 
Press the [Camera switch] key to activate the manual selection of the camera . Use the 

[Plus / +] and [Minus / -] keys to select the connected cameras . Press the [Camera switch] 

key again to deactivate the manual camera selection (→ „4.1 Camera switch“).

Day / Night setting Select between day and night setting . 

Press the [Day / Night setting] key to change the brightness and colour palette of the 

display (→ „4.2 Day / Night setting“).

Contrast

Set the contrast .
Press the  [Contrast] key to activate contrast setting . Use the [Plus / +] and [Minus / -] keys 

to change the contrast . Press the  [Contrast] key again to deactivate contrast setting  

(→ „4.3 Contrast“).

Brightness

Set the brightness .
Press the [Brightness] key to activate brightness setting . Use the [Plus / +] and  

[Minus / -] keys to change the brightness . Press the [Brightness] key again to deactivate 

the brightness setting (→ „4.4 Brightness“).

Scan /  

Back in menu

Display the image of the connected cameras one after the other .
Go Back in menu .
Press the [Scan / Back in menu] key to display the view of the connected cameras one 

after the other or navigate back in menu (→ „4.6 Scan / Back in menu“).

Minus / -

Select next menu item .
Navigate to the left in the menu .
Press the [Minus / -] key to navigate to the next menu item or to the left .

Plus / +

Select the previous menu item .
Navigate to the right in the menu .
Press the [Plus / +] key to navigate to the previous menu item or to the right .

Enter / Standby

Display standby mode and details about the firmware . 
Acknowledge the menu item .
Press the [Enter / Standby] key to activate the standby mode and to display the details 

about the firmware or to confirm the selected menu item .

Summary of Contents for E2M231

Page 1: ...Operating instructions Monitor for analogue cameras E2M231 E2M232 706451 00 02 2018 UK ...

Page 2: ...ration 7 4 6 Scan Back in menu 7 5 User menu 8 5 1 Language 8 5 2 Camera settings 9 6 Service menu 10 6 1 Camera settings 10 6 2 Camera name 10 6 3 System settings 11 6 3 1 Language 11 6 3 2 On screen display 11 6 3 3 Keyboard 12 6 3 4 Power supply settings 12 6 3 5 LCD backlight 13 6 3 6 Scanning 13 6 3 7 Camera switch 14 6 3 8 Tacho settings 14 6 3 9 Default settings 15 6 4 Info 15 7 Glossary 16...

Page 3: ...ies This device contains maybe modified open source software which is subject to special licensing terms For copyright information and licensing terms please refer to www ifm com int GNU For software subject to the GNU General Public License or the GNU Lesser General Public License the source code can be requested against payment of the copying and shipping costs ...

Page 4: ... wrong installation or incorrect handling can seriously affect the safety of operators and machinery 2 2 Target group These instructions are intended for authorised persons according to the EMC and low voltage directives The device must be installed connected and put into operation by a qualified electrician 2 3 Electrical connection Disconnect the unit externally before handling it The connection...

Page 5: ...switch key again to deactivate the manual camera selection 4 1 Camera switch Day Night setting Select between day and night setting Press the Day Night setting key to change the brightness and colour palette of the display 4 2 Day Night setting Contrast Set the contrast Press the Contrast key to activate contrast setting Use the Plus and Minus keys to change the contrast Press the Contrast key aga...

Page 6: ...ng Description ABC Automatic setting of the brightness depending on the ambient light The brightness sensor is above the Plus key ABC RED Automatic setting of the brightness depending on the ambient light A red colour palette is used The brightness sensor is above the Plus key ABC BLUE Automatic setting of the brightness depending on the ambient light A blue colour palette is used The brightness s...

Page 7: ...ed The brightness must be set separately for each connected camera 4 5 Colour saturation Press the Contrast and Brightness keys simultaneously to activate colour saturation setting Use the Plus and Minus keys to set the colour saturation The set colour saturation is permanently stored The colour saturation must be set separately for each connected camera 4 6 Scan Back in menu The Scan Back in menu...

Page 8: ...ttings are available in the user menu Language 5 1 Language Camera settings 5 2 Camera settings The user menu is deactivated as default and has to be activated in the Service menu 6 3 3 Keyboard 5 1 Language The language of the on screen display OSD is set in the Language menu The following languages are available English Dutch German French Czech Hungarian Italian Polish Portuguese Spanish Turkis...

Page 9: ... for each connected camera Hor marker Activate or deactivate horizontal marking line Marker pos Set position of the horizontal marking line With default setting the marking line is in the middle of the screen 50 Vert marker Activate or deactivate vertical marking line Marker pos Set position of the vertical marking line With default setting the marking line is in the middle of the screen 50 Gratic...

Page 10: ...f the display Saturation Set the colour saturation of the display Switch delay Activate the switching delay This setting is required if the wire is to be controlled with an uninterrupted signal e g from an indicator Hor marker Activate or deactivate horizontal marking line Marker pos Set position of the horizontal marking line With default setting the marking line is in the middle of the screen 50...

Page 11: ...n screen display OSD timeout Suppress the on screen displays after the time set in seconds The OFF setting permanently activates the on screen displays The ON setting deactivates the on screen displays OSD Position Set the horizontal position of the on screen displays Info transparency Set the transparency of the on screen displays Menu transparency Set the transparency of the menu Disclaimer tran...

Page 12: ...cess to the camera settings Standby Lock access to the standby mode 6 3 4 Power supply settings The standby mode of the device is set in the Power settings menu Standby mode Set one of the following modes for standby MNU Use the Enter Standby key to activate the standby menu 4 Function keys IMM Use the Enter Standby key to activate the standby mode directly 2 S Keep the Enter Standby key pressed f...

Page 13: ...Minus keys to vary the brightness between 50 and 100 NIT Night mode The brightness is set to 20 Use the Plus and Minus keys the vary the brightness between 0 and 50 N_R Night mode The brightness is set to 20 A red colour palette is used Use the Plus and Minus keys to vary the brightness between 0 and 50 N_B Night mode The brightness is set to 20 A blue colour palette is used Use the Plus and Minus...

Page 14: ...of the cameras is set AUX wire function Set the mode of the wires The following modes are available OFF Deactivate the wires TCH Control the cameras via a tachometer Connect the grey wire to the tachometer and the yellow wire to the parking brake KEY Deactivate the keyboard with the grey wire C Select the connected cameras with the wires Pulses per meter Set the speed pulses per metre resolution i...

Page 15: ...value is 45 As standard the value of Select defaults must not be changed Contact the manufacturer for more details Restore defaults Reset all settings and restore the default values All settings are lost at once and without further enquiry The former settings cannot be restored 6 4 Info In the Info menu information about the hardware and software used is displayed The displayed information is very...

Page 16: ...k in menu key does not function as expected The images of the connected camera are not displayed one after the other In addition the LED next to the Camera switch key flashes Solution Press Camera switch key 8 2 Malfunction of camera 3 Camera 3 is active and does not display an image Solution Keep the Scan Back in menu key pressed for 15 seconds 8 3 Device shuts off after 2 seconds The device shut...

Page 17: ...17 E2M231 E2M232 monitor for analogue cameras UK ...

Reviews: