8.4 LED indicators DTE802/DTE902
The following LED indicators only apply to DTE802/DTE902�
8.4.1 LED Mod (module status)
LED red
LED green
State
Note
Off
Off
No voltage supply
Check the voltage supply
Off
Flashes
Ready for operation
Device is not configured�
There is no exchange of data:
►
Check the connection of
the Ethernet/IP scanner�
►
Check the parameter
setting of the configuration
assembly�
Off
On
Normal operation
Connection to the EtherNet/
IP scanner is established�
The device is configured� The
data transfer is running�
Flashes
Off
Minor error
A connection to the EtherNet/
IP scanner was not
established:
►
Check the voltage supply�
►
Check the configuration of
the device�
On
Off
Major error
Software / hardware error of
the device:
►
Restart the device�
> If the error remains, send
the device for service�
Flashes
Flashes
Self-test
Starting phase of the device