![IFM DTE103 Device Manual Download Page 61](http://html.mh-extra.com/html/ifm/dte103/dte103_device-manual_620793061.webp)
61
UK
13.4.2
Payload traffic view
Command request send by controller:
18
0A000200000000000000000000000000000000
18
10001000000000000000000000000000000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Controller: Read 10 bytes from channel IO-1 at address 0x0002 and 16 bytes at address 0x0010 from
channel IO-2 .
Response send by evaluation unit when command has been processed:
19
0A112233445566778899AA0000000000000000
11
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Evaluation unit: Send read User data of channel IO-1, channel IO-2 is not ready with response .
. . .
19
0A112233445566778899AA0000000000000000
19
101112131415161718191A1B1C1D1E1F000000
00
00000000000000000000000000000000000000
00
00000000000000000000000000000000000000
Evaluation unit: Send “Tag is in field” and User data with length of 16 bytes from channel IO-1 and IO .