20
If the firmware update fail or the read/write head is not detected by the evaluation unit at the selected IO-
port, the read/write head is accessible via web browser and the following URL:
http://<
IP-ADDRESS
>/rwhupdate?ioport=<
IO-CHANNEL
>1&anttype=<
ANTENNA_TYPE
> &fwVersion=
<
NUMBER
>&setLng=<
LANGUAGE
>
Parameter name
Description
Remark
IP-ADDRESS
IP address of the evaluation unit [XXX .XXX .XXX .XXX]
IPV4 address
IO-CHANNEL
IO-Channel number [1…4]
-
ANTENNA_TYPE
Article number of the read/write head [e .g . ANT512]
6 digit article number
NUMBER
Firmware number [01]
2 digit number . Shall be
set to “01”
LANGUAGE
Language of the website [de, en, es, fr, it, ko, pt, ru, zh] -
Example of URL:
http://192 .168 .0 .79/diagrwh?ioport=1&anttype=ANT513&fwVersion=01&setLng=en
After finishing the firmware update of the read/write head, enter the URL of the evaluation unit to
return to the main menu