Operating instructions

Compact speed monitor M18

DI604A

11473499 / 00   07 / 2022

GB

Summary of Contents for DI604A

Page 1: ...Operating instructions Compact speed monitor M18 DI604A 11473499 00 07 2022 GB ...

Page 2: ...ameter setting 14 8 1 Parameter setting via the IO Link interface 14 8 1 1 P n 14 8 1 2 ou1 14 8 1 3 ou2 14 8 1 4 SSC1 x Param SP1 14 8 1 5 SSC1 x Param SP2 15 8 1 6 SSC1 x Config Logic 15 8 1 7 SSC1 x Config Mode 15 8 1 8 SSC1 x Config Hysteresis 15 8 1 9 SSC1 x Delay dS 15 8 1 10 SSC1 x Delay dS 15 8 1 11 PrSC 15 8 1 12 Teach offset 15 8 1 13 TI Select 15 8 1 14 Access locks to the unit Local pa...

Page 3: ...ls and further information using the QR code on the unit packaging or at www ifm com 1 1 Symbols used Requirement Instructions Reaction result Designation of keys buttons or indications Cross reference Important note Non compliance may result in malfunction or interference Information Supplementary note ...

Page 4: ...ly use the product for its intended purpose Ò Intended use If the operating instructions or the technical data are not adhered to personal injury and or damage to property may occur The manufacturer assumes no liability or warranty for any consequences caused by tampering with the product or incorrect use by the operator Installation electrical connection set up operation and maintenance of the pr...

Page 5: ...output The pulse output enables external evaluation of the damping pulses in both operating modes In IO Link mode the measured value jams and SSC bits can be read as cyclic process data and transferred to a controller and parameters can be read and written acyclically for configuration identification and diagnostics In the mode without IO Link communication the unit is in switching mode SIO mode w...

Page 6: ...ulses min is measured There is no underload An overload is present at over 32 000 0 pulses min 533 Hz 4 1 Single point mode SP1 H SSC 0 PDV OFF ON Fig 1 Normally open low active factory setting SP1 Switch off point SP1 H Switch on point If a set rotational speed is not reached the transistor output will signal this as non conducting H SSC 0 PDV SP1 ON OFF Fig 2 Normally closed high active SP1 Swit...

Page 7: ... Switch on point SP2 H Switch off point SP1 Switch on point SP1 H Switch off point If the set speed range is left the transistor output will signal this as conducting Imp min 2500 3000 2750 3250 3500 2250 2000 1250 1500 1750 1000 750 500 250 0 1 0 1 0 OUT 2 3 4 1 OUT SP1 H SP1 SP2 SP2 H t 1 Power on delay time 2 Start up delay 3 Normally open low active 4 Normally closed high active It is also pos...

Page 8: ...SP2 t 1 Power on delay time 2 Start up delay 3 Normally open low active 4 Normally closed high active It is also possible to configure SP1 as the lower switch point and SP2 as the upper switch point The lower switch point must be at least 10 lower than the higher switch point 4 4 IO Link mode IO Link allows the configuration of internal parameters such as switching threshold start up delay and swi...

Page 9: ...icates the switching status of the sensor 4 5 1 Switching function normally open low active Transistor output LED yellow State Conducting ON On Rotational speed SP H and during start up delay Non conducting OFF Off Rotational speed SP SP switch point H hysteresis 4 5 2 Switching function normally closed high active Transistor output LED yellow State Non conducting OFF Off Rotational speed SP H and...

Page 10: ...d in teach In the event of underspeed 2 880 pulses min the switching output is blocked See Teach offset Ò 15 4 8 Prescaler The prescaler is a divider to calculate the actual rpm as process data value PDV in an application with several cams on an axis The measurement limit is reduced by this divider Recommendation Set the prescaler to the number of cams for one revolution This makes it possible to ...

Page 11: ...Fig 8 Mounting specifications u Fix the unit using a bracket and secure it by means of the nuts provided so that it cannot work loose u Adhere to the above mounting specifications to ensure a correct function u Install the unit non flush 2xSn Fig 9 Cylindrical design non flush ...

Page 12: ...ational and international regulations for the installation of electrical equipment u Disconnect power u Connect the unit as follows 4 3 2 1 L 1 BN 2 WH 4 BK 3 BU L 1 L 2 Pulse output the pulse sequence corre sponds to the damping frequency 3 L 4 Switching output adjustable IO Link com munication Factory setting PNP normally open ...

Page 13: ...conducting operating mode Off Switching output non conducting operating mode Flashing See Parameter setting mode Ò 17 Double flash Parameters saved parameter setting mode Green On Unit damped installation set up mode Off Unit not damped installation set up mode Flashing different flashing frequencies Parameter setting mode Ò 17 damping frequency up to max 8 Hz installation set up mode visual local...

Page 14: ... Link interface The following parameters can be checked set via the IO Link interface among others 8 1 1 P n Output polarity for the switching outputs PnP factory setting nPn 8 1 2 ou1 Output configuration for OUT1 OFF output off SSC1 1 factory setting 8 1 3 ou2 Output configuration for OUT2 ImP pulse output factory setting OFF output off SSC1 2 When configured as a pulse output the output switche...

Page 15: ...Hysteresis Switch point hysteresis 10 30 factory setting 10 8 1 9 SSC1 x Delay dS Switching delay Adjustable switch on delay time of the output in ms 0 60 000 ms factory setting 0 ms 8 1 10 SSC1 x Delay dS Switch off delay Adjustable switch off delay time of the output in ms 0 60 000 ms factory setting 0 ms 8 1 11 PrSC Prescaler divider to calculate the actual rpm 1 99 factory setting 1 See Presca...

Page 16: ...stomer specific function tag of the unit max 32 characters long Default value can be freely defined by the customer 8 1 18 Location Tag Customer specific location tag of the unit max 32 characters long Default value can be freely defined by the customer 8 1 19 Locator Start Used to identify a unit The LED quickly flashes green 2x per second 8 1 20 Locator Stop Deactivates the flashing of the LED T...

Page 17: ...ter setting is possible via the keys on the unit If no key is pressed for more than 120 s the unit will automatically exit the parameter setting or installation set up mode Any unsaved parameter changes will be lost 8 2 1 Parameter setting mode The following parameters can be set via the unit keys 1 Switch point SP1 2 1 24 000 pulses min factory setting 100 pulses min 2 Start up delay 0 15 s steps...

Page 18: ...ashes green with a frequency of 1 Hz during these 10 s w The LED flashes yellow twice for confirmation then green with a frequency of 1 Hz w The unit is in the parameter setting mode for the switch point u Set the push ring to to change to the parameter setting mode for the start up delay OR Set the push ring to to teach SP1 w The LED flashes green with the damping frequency however with a maximum...

Page 19: ... flash and the current value is 0 s Press to increase the time again in steps of 1 s u Set the push ring to to save the set value w The LED flashes yellow twice for confirmation then green with a frequency of 2 Hz w The unit is still in the parameter setting mode for the start up delay u Set the push ring to to change to the parameter setting mode for the output function w The LED quickly flashes ...

Page 20: ...ashes yellow twice for confirmation w The application specific parameters have been reset to the factory settings 8 3 Teach The switching threshold is set via the teach function This can also be done when the unit is installed as well as with constant speed equipment The IO Link commands Teach SP1 and Teach SP2 allow you to teach both switching thresholds separately The keys on the unit only let y...

Page 21: ...tion is maintenance free Ensure the following for a correct function u Keep the sensing face and the clear space free of metal deposits and foreign bodies u Do not operate devices with high field intensity e g mobile phones at close range to the speed monitor ...

Page 22: ...nance repair and disposal The operation of the unit is maintenance free Only the manufacturer is allowed to repair the unit u After use dispose of the device in an environmentally friendly way in accordance with the applicable national regulations ...