1  Preliminary note

•  An instruction is indicated by „►“: 

Example: ► Mount the unit as shown�

Important note 

Non-compliance can result in malfunction or interference�

Information 

Supplementary note�

2  Safety instructions

•  Please read the operating instructions prior to set-up of the device� Ensure that 

the product is suitable for your application without any restrictions�

•  The unit conforms to the relevant regulations and EC directives�
•  Improper or non-intended use may lead to malfunctions of the unit or to 

unwanted effects in your application�

•  Installation, electrical connection, set-up, operation and maintenance of the 

unit must only be carried out by qualified personnel authorised by the machine 

operator�

3  Functions and features

•  Vibration detection of machines and equipment

•  For connection to diagnostic electronics VSExxx

4  Electrical connection

The unit must be connected by a qualified electrician�

The national and international regulations for the installation of electrical 

equipment must be adhered to�

 

► Disconnect power�

 

► Connect the unit�

Wiring

blue: GND / black: test / brown: L+ / white: out

shield wire: screen

Summary of Contents for VSA003

Page 1: ...Installation instructions Vibration sensor VSA003 VSA004 VSA005 704577 02 09 2010 UK ...

Page 2: ...3 3 Functions and features 3 4 Electrical connection 3 4 1 Use of a screened cable for VSAx sensors 4 4 2 Setting instructions 4 5 Installation 4 6 Scale drawing 5 7 Approval Limited voltage Current 5 8 Maintenance repair and disposal 5 9 Technical data 5 ...

Page 3: ...ed use may lead to malfunctions of the unit or to unwanted effects in your application Installation electrical connection set up operation and maintenance of the unit must only be carried out by qualified personnel authorised by the machine operator 3 Functions and features Vibration detection of machines and equipment For connection to diagnostic electronics VSExxx 4 Electrical connection The uni...

Page 4: ...nsor 1 17500 mg VSA004 VSA005 settings Sensors Sensor 1 25000 mg If the sensor is connected to channel 2 VSA003 settings Sensors Sensor 2 17500 mg VSA004 VSA005 settings Sensors Sensor 2 25000 mg etc 5 Installation Mount only in a thick housing wall and vertical to the machine surface close to the bearing or at the end shield Ensure that the signal direction is correct Ensure a safe vibration tran...

Page 5: ...vice shall be supplied from an isolating transformer having a secondary Listed fuse rated 1 0 A 8 Maintenance repair and disposal If used correctly no maintenance and repair measures are necessary After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations 9 Technical data Technical data and further information at www ifm com ...

Reviews: