6
Setting of the sensitivity with moving objects*
6.2
1
Activate the programming mode of the unit�
Press for about 2 s until the red
►
LED flashes�
The red LED goes out; the yellow and green LEDs flash alternately�
>
The unit is in the programming mode�
>
2
Allow objects to pass through the detection area during the measurement (about
►
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
Press once�
►
The yellow and green LEDs go out for approx� 1 s, then flash again alternately�
>
3
Allow objects to pass through the detection area during the measurement (about
►
1 s) (number of the objects between min. 8 Hz and max. switching frequency).
Press once�
►
The yellow and green LEDs go out for approx� 1 s, after approx� 3 s the green
>
LED is on�
The unit is in the operating mode�
>
* The sensitivity can also be set in exactly the same way using the programming wire
(pin 2 / WH). To activate the functions the programming wire is connected for the appropriate
time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units. Feedback: If setting
was not successful via the programming wire, the output will switch for 2 s� The unit then
reverts to the operating mode with the sensitivity unchanged�