5
UK
2
Set the sensitivity with object�
Press once�
►
The yellow and green LEDs go out for approx� 1 s, then flash again alternately�
>
3
Set the sensitivity without object�
Press once
►
The yellow and green LEDs go out for approx� 1 s,
>
after approx� 3 s the green LED is on�
The unit is in the operating mode�
>
You can also proceed in reverse order: first setting without the object, then with
the object�
* The sensitivity can also be set in exactly the same way using the programming wire
(pin 2 / WH). To activate the functions the programming wire is connected for the appropriate
time to L+ (pin 1 / BN) for PNP units or to L- (pin 3 / BU) for NPN units. Feedback: If setting
was not successful via the programming wire, the output will switch for 2 s� The unit then
reverts to the operating mode with the sensitivity unchanged�
If the setting of the sensitivity is not possible (e.g. object signal and back
-
ground signal are about the same), the red LED flashes after step 3 for ap
-
prox� 2 s� The unit then passes into the operating mode with the sensitivity
being unchanged�
If the setting button is not activated for 15 minutes during the programming
process, the unit passes automatically into the operating mode with the sen-
sitivity being unchanged�