1  Preliminary note

1.1  Symbols used

► Instructions

>

Reaction, result

[…] Designation of pushbuttons, buttons or indications

→ Cross-reference

Important note 

Non-compliance can result in malfunction or interference�

Information 

Supplementary note�

2  Safety instructions

 

● Please read the product description prior to set-up of the unit� Ensure that the 

product is suitable for your application without any restrictions� 

 

● If the operating instructions or the technical data are not adhered to, personal 

injury and/or damage to property can occur�

 

● Installation, electrical connection, set-up, operation and maintenance of the 

unit must only be carried out by qualified personnel authorised by the machine 

operator�

 

● The unit complies with the standard EN 61000-6-4� The unit may cause radio 

interference in domestic areas� If interference occurs, the user must take ap-

propriate remedial actions�

Summary of Contents for efector160 LI214 Series

Page 1: ...Operating instructions Binary level sensor LI214x 704776 00 10 2010 UK...

Page 2: ...rinciple 4 4 2 Features of the unit 5 5 Installation 5 5 1 Installation location environment 5 5 2 Mounting 6 5 3 Set the installation depth 6 6 Electrical connection 7 7 Operating and display element...

Page 3: ...t the product is suitable for your application without any restrictions If the operating instructions or the technical data are not adhered to personal injury and or damage to property can occur Insta...

Page 4: ...te mounting accessories chapter 5 2 Installation procedure 4 Function 4 1 Measuring principle The unit operates to the capacitive measuring principle By direct contact with the medium the unit detects...

Page 5: ...le detection of media with a very low dielectric constant e g oil The installation depth determines the level 5 3 The unit is virtually immune to almost any kind of build up on the probe The position...

Page 6: ...ssure rating of 0 5 bar E43006 flange plate 65 80 with clamp adapter aluminium pressure rating of 0 5 bar E43007 flange plate 54 52x52 with clamp adapter aluminium pressure rating of 0 5 bar E43016 mo...

Page 7: ...age supply to EN 50178 SELV PELV Disconnect power Connect the unit as follows 3 1 4 2 L L 1 4 3 Pin1 L Pin4 switching output NC Pin3 L Core colours of ifm sockets 1 BN brown 3 BU blue 4 BK black 7 Ope...

Page 8: ...rocess the yellow LED is lit con tinuously unit is in the operating mode sensor zone not covered 8 2 Set to the full vessel The empty adjustment is sufficient for media with a low dielectric constant...

Page 9: ...ation When the supply voltage has been applied the unit is in the operating mode It carries out its measurement and evaluation functions and switches the output Operation indication by LED LED Status...

Page 10: ...nstant medium 1 8 Max tank pressure bar 0 51 Housing materials PP GF orange TPE U Materials wetted parts PP Protection IP 65 IP 67 Protection class II Ambient temperature C 0 60 Medium temperature oil...