An analogue current signal or a pulse signal can be connected to the analogue 

inputs� They can be used as speed input for vibration diagnostics, as trigger of 

a measurement or for process value monitoring�

• 

An analogue current signal can also be connected to the dynamic inputs to 

monitor max� 4 more process values�  

Moreover up to 4 vibration sensors from ifm (types VSA, VSP) or sensors with 

an IEPE standard signal can be connected�

• 

The possibilities of signal monitoring and signal analysis depend on the 

respective firmware version� The current firmware and operating software can 

be downloaded from the download area on ifm's website�

• 

The alarm states of the monitoring tasks (process values and/or objects) are 

indicated in the diagnostic electronics and/or the 2 hardware outputs via the 

LED of the respective sensor� The hardware outputs can be configured as 2 x 

binary (NO/NC, PNP) or as 1 x analogue (0/4…20 mA) and 1x binary (NO/NC, 

PNP)�

• 

The 8 digital I/Os of the diagnostic electronics can be used either as additional 

alarm outputs (NO/NC, PNP) or as digital inputs (versions, reset counter)�

Examples of the firmware functions are:
• 

Online monitoring

 -of process values (analogue signals) for current value above and/or below the 

limit value�

 -of up to 24 indicators (objects) of the dynamic signals (e�g� vibration) in the 

time range or frequency range (FFT and/or H-FFT)�  

Monitoring of the objects is possible with regard to up to 2 process categories 

(e�g� load and rotational speed)�

• 

Internal trend memory with RTC time stamp with flexible storage intervals for 

each object�

• 

Counter function

For monitoring and evaluation of the dynamic signals (e�g� vibration) the firmware 

provides the following tools or settings:

 -Spectral analysis FFT, envelope-curve FFT, trend analysis
 -Velocity monitoring to ISO 10816 with variable filter setting

All parameters are set and/or the monitoring tasks configured (process values 

and/or objects) via the PC software, article number VES004�

Summary of Contents for efector 800 VSE100

Page 1: ...Operating instructions Diagnostic electronics for vibration sensors VSE100 VYE102 VYE107 80227555 00 02 2015 UK ...

Page 2: ...rical connection 5 5 1 Limited voltage current 6 5 2 Wiring 6 5 2 1 Wiring of the sensors 1 4 S1 S4 according to the sensor 7 5 3 Connection of the sensors 8 5 3 1 Monitoring the sensor cable 8 5 4 Ethernet connection 9 6 Operation 9 6 1 Settings parameter setting 9 7 Indicators LEDs 10 8 Maintenance repair and disposal 11 9 Scale drawing 11 ...

Page 3: ...structions 3 Functions and features The diagnostic electronics has 2 analogue inputs and 4 dynamic inputs These inputs can be used for process value monitoring vibration monitoring vibration diagnostics or analysis of other dynamic signals The final function depends on the firmware version The current firmware and operating software can be downloaded from the download area on ifm electronic s webs...

Page 4: ...O NC PNP or as 1 x analogue 0 4 20 mA and 1x binary NO NC PNP The 8 digital I Os of the diagnostic electronics can be used either as additional alarm outputs NO NC PNP or as digital inputs versions reset counter Examples of the firmware functions are Online monitoring of process values analogue signals for current value above and or below the limit value of up to 24 indicators objects of the dynam...

Page 5: ...tom of the control cabinet to enable air circulation to avoid excessive heating Prevent the penetration of conductive or other dirt during installation and wiring 4 1 Installation of the sensors Adhere to the installation instructions supplied with the sensor 5 Electrical connection The unit must be connected by a qualified electrician The national and international regulations for the installatio...

Page 6: ...ted a max 5 A for voltages 0 20 Vrms 0 28 3 Vp or b 100 Vp for voltages of 20 30 Vrms 28 3 42 4 Vp 5 2 Wiring L 24 V DC 20 18 17 20 19 14 13 16 15 22 21 24 23 6 5 8 7 2 1 4 3 10 9 12 11 L OU 1 switch analog OU 2 switch IN 1 0 4 20 mA pulse GND 1 IN 2 0 4 20 mA pulse GND 2 1 2 3 4 BN WH BU BK 4 3 2 1 BK BU WH BN I O 7 30 29 32 31 34 33 36 35 26 25 28 27 43 44 41 42 47 48 45 46 39 40 37 38 GND I O 8...

Page 7: ...0 mA WH cur rent input IEPE Current input 0 20 mA 11 14 18 22 BU GND BK GND GND IEPE GND 12 13 17 21 BK Self test output Do not use Do not use Do not use Protect the supply voltage externally max 2 A The ground GND of the DC supply is directly connected with the ground GND of the sensor supply The SELV criteria must therefore be met for the DC supply safety extra low voltage circuit electrically i...

Page 8: ...oltages are applied to the sensor or transferred to the device Sensor and diagnostic electronics supply are not electrically isolated 5 3 1 Monitoring the sensor cable In case of wire break short circuit or faulty measuring cell the output OU 1 provides 22 mA 2 and the output OU 2 clocks at 1 Hz the SENS LED flashes green ...

Page 9: ...d simultaneously Alarm states of the set objects can be displayed on up to 2 digital outputs Output 1 OU 1 can also be used as analogue output e g for transferring the total vibrations to ISO 10816 Alarm states of objects that are assigned to one of the 4 dynamic inputs sensors 1 4 are displayed by the respective LEDs of the diagnostic electronics The digital I Os can also be used as alarm outputs...

Page 10: ...lternately Teach process active LED 2 ditto for sensor 2 LED 3 ditto for sensor 3 LED 4 ditto for sensor 4 LED 5 for system Lights green System OK monitoring running Lights yellow System OK no monito ring due to parameter setting self test or FFT mode Flashes green yellow alternately Monitoring not possible faulty parameter set Flashes green red alternately System error EEPROM faulty other states ...

Page 11: ...e manufacturer is allowed to repair the unit After use dispose of the unit in an environmentally friendly way in accordance with the applicable national regulations 9 Scale drawing 1 Ethernet interface 2 Combicon connectors Technical data and further information at www ifm com Select your country Data sheet search ...

Reviews: