EN
4 - HANDLING AND INSTALLATION
BOSS 332/545/552 HD
4 - Pag. 32 / 32
4.10 PNEUMATIC
CONNECTION
• Fill the tank of lubricator "A" removing plug "B"
or cup "C"; the oil level must reach the MAX.
reference.
See the "Technical Data" section, Ch. 6, for the
oil comparative table.
• Connect the pipe of the pneumatic network to
the coupling D (1/4"Gas). Install a 3-way cock
at the beginning of this connection so as to
perform the sectioning and the pressure
release. By means of the knob "E", adjust the
pressure to 6 bar.
• Check air lubrication (1-12 drops per 1,000 l of
air); adjust by turning the screw "F".
IMPORTANT:
the supply air must be filtered.
4.11 SOFTWARE
PARAMETERIZATION
The bar feeder software should be correctly parameterized according to the working needs and
the lathe type.
For further information on how to carry out this operation, check the "Keyboard instruction
manual".
Summary of Contents for BOSS 332
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ......
Page 10: ......
Page 15: ...1 GENERAL INFORMATION BOSS 332 545 552 HD EN 1 Pag 5 5 ...
Page 47: ...EN 2 TECHNICAL INFORMATION BOSS 332 545 552 HD 2 Pag 32 32 ...
Page 53: ...EN 3 SAFETY PROCEDURES GENERAL INFORMATION BOSS 332 545 552 HD 3 Pag 6 6 ...
Page 140: ...6 USE AND OPERATION BOSS 332 545 552 HD EN 6 Pag 21 24 Press ...
Page 143: ...EN 6 USE AND OPERATION BOSS 332 545 552 HD 6 Pag 24 24 ...
Page 151: ...EN 7 BAR FEEDER MAINTENANCE BOSS 332 545 552 HD 7 Pag 8 8 ...
Page 155: ...EN 8 TROUBLES CAUSES CURES BOSS 332 545 552 HD 8 Pag 4 4 ...
Page 179: ...EN 11 COLLETS BOSS 332 545 552 HD 11 Pag 2 34 ...
Page 188: ...11 COLLETS BOSS 332 545 552 HD EN 11 Pag 11 34 ...