TANK -820-H61 E mbedded S ys tem
P age 79
Aptio Setup Utility – Copyright (C) 2011 American Megatrends, Inc.
Advanced
Smart Fan Mode Configuration
Smart Fan control
[Auto PWM Mode]
Temperature of Off
75
Temperature of Start
80
Start PWM
30
Slope(Duty Cycle)
[4]
System Smart Fan control
[Auto Duty-Cycle Mode]
First Boundary Temperature
60
Second Boundary Temperature
50
Third Boundary Temperature
40
Fourth Boundary Temperature
30
Smart Fan Mode Select
--------------------
: Select Screen
↑
↓
: Select Item
Enter Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized
Defaults
F4: Save & Exit
ESC: Exit
Version 2.14.1219. Copyright (C) 2011 American Megatrends, Inc.
BIOS Menu 16: FAN Configuration
S mart F an control [Auto P WM Mode]
Use the
Smart Fan control
BIOS option to configure the CPU Smart Fan.
Full Mode
Fan is on all the time
Manual PWM Mode
The fan spins at the speed set in the manual
setting
Auto PWM Mode
D
EFAULT
The fan adjusts its speed using these
settings:
Temperature of Start
Temperature of Off
Start PWM
Slope (Duty Cycle)
Temperature of Off [75]
WARNING:
Setting this value too high may cause the fan to speed up only when
Summary of Contents for TANK-820-H61 Series
Page 14: ...TANK 820 H61 E mbedded S ys tem Page 1 Chapter 1 1 Introduction ...
Page 25: ...TANK 820 H61 E mbedded S ys tem Page 12 Chapter 2 2 Unpacking ...
Page 30: ...TANK 820 H61 E mbedded S ys tem Page 17 Chapter 3 3 Ins tallation ...
Page 55: ...TANK 820 H61 E mbedded S ys tem Page 42 4 S ys tem Motherboard Chapter 4 ...
Page 68: ...TANK 820 H61 E mbedded S ys tem Page 55 Chapter 5 5 B IOS ...
Page 109: ...TANK 820 H61 E mbedded S ys tem Page 96 Appendix A A R egulatory Compliance ...
Page 115: ...TANK 820 H61 E mbedded S ys tem Page 102 Appendix B B S afety Precautions ...
Page 120: ...TANK 820 H61 E mbedded S ys tem Page 107 Appendix C C Hazardous Materials Dis clos ure ...