ICE-BT-T10 COM Express Module 

Page i

User Manual 

COM Express R2.1 Module (Type 10), 

  22nm Intel® Atom™ or Celeron® Processor 

2 GB DDR3, EEPROM and RoHS Compliant 

 

MODEL: 

ICE-BT-T10 

Rev. 1.01 – November 4, 2015 

Summary of Contents for ICE-BT-T10-E38151

Page 1: ...ICE BT T10 COM Express Module Page i User Manual COM Express R2 1 Module Type 10 22nm Intel Atom or Celeron Processor 2 GB DDR3 EEPROM and RoHS Compliant MODEL ICE BT T10 Rev 1 01 November 4 2015 ...

Page 2: ...ICE BT T10 COM Express Module Page ii Revision Date Version Changes November 4 2015 1 01 Modified B89 pin definition in Table 3 2 August 27 2014 1 00 Initial release ...

Page 3: ...mages arising out of the use or inability to use the product or documentation even if advised of the possibility of such damages This document contains proprietary information protected by copyright All rights are reserved No part of this manual may be reproduced by any mechanical electronic or other means in any form without prior written permission of the manufacturer TRADEMARKS All registered t...

Page 4: ...AUTION Cautionary messages should be heeded to help reduce the chance of losing data or damaging the product NOTE These messages inform the reader of essential but non critical information These messages should be read carefully as any directions or instructions contained therein can help avoid making mistakes HOT SURFACE This symbol indicates a hot surface that should not be touched without takin...

Page 5: ...G PRECAUTIONS 11 2 3 PACKING LIST 12 2 4 OPTIONAL ITEMS 13 3 CONNECTORS 14 3 1 PERIPHERAL INTERFACE CONNECTORS 15 3 1 1 ICE BT T10 Layout 15 3 1 2 Peripheral Interface Connectors 15 3 2 INTERNAL PERIPHERAL CONNECTORS 16 3 2 1 COM Express Connector 16 3 2 2 SPI Flash Connector 20 4 INSTALLATION 21 4 1 ANTI STATIC PRECAUTIONS 22 4 2 INSTALLATION CONSIDERATIONS 22 4 3 MOUNTING ICE BT T10TO BASEBOARD ...

Page 6: ... Console Redirection 39 5 3 6 CPU Configuration 42 5 3 7 IDE Configuration 44 5 3 8 SDIO Configuration 45 5 3 9 USB Configuration 46 5 4 CHIPSET 47 5 4 1 North Bridge 48 5 4 1 1 Intel IGD Configuration 49 5 4 2 South Bridge Configuration 51 5 4 2 1 PCI Express Configuration 52 5 5 SECURITY 53 5 6 BOOT 54 5 7 SAVE EXIT 56 6 SOFTWARE DRIVERS 58 6 1 AVAILABLE SOFTWARE DRIVERS 59 6 2 STARTING THE DRIV...

Page 7: ...T10 COM Express Module Page vii D WATCHDOG TIMER 81 E HAZARDOUS MATERIALS DISCLOSURE 84 E 1 HAZARDOUS MATERIALS DISCLOSURE TABLE FOR IPB PRODUCTS CERTIFIED AS ROHS COMPLIANT UNDER 2002 95 EC WITHOUT MERCURY 85 ...

Page 8: ... 2 Drivers 60 Figure 6 3 Chipset Driver Welcome Screen 61 Figure 6 4 Chipset Driver License Agreement 62 Figure 6 5 Chipset Driver Read Me File 62 Figure 6 6 Chipset Driver Setup Operations 63 Figure 6 7 Chipset Driver Installation Finish Screen 63 Figure 6 8 Graphics Driver License Agreement 65 Figure 6 9 Graphics Driver Read Me File 65 Figure 6 10 Graphics Driver Setup Operations 66 Figure 6 11 ...

Page 9: ...riations 3 Table 1 2 ICE BT T10 Specifications 9 Table 2 1 Packing List 12 Table 2 2 Optional Items 13 Table 3 1 Peripheral Interface Connectors 15 Table 3 2 COM Express Connector Pin Definitions 20 Table 3 3 SPI Flash Connector Pinouts 20 Table 5 1 BIOS Navigation Keys 29 ...

Page 10: ...37 BIOS Menu 8 RTC Wake Settings 38 BIOS Menu 9 Serial Port Console Redirection 39 BIOS Menu 10 CPU Configuration 42 BIOS Menu 11 SATA Configuration 44 BIOS Menu 12 USB Configuration 45 BIOS Menu 13 USB Configuration 46 BIOS Menu 14 Chipset 47 BIOS Menu 15 North Bridge Configuration 48 BIOS Menu 16 Graphics Configuration 49 BIOS Menu 17 PCH IO Configuration 51 BIOS Menu 18 PCI Express Configuratio...

Page 11: ...ICE BT T10 COM Express Module Page 1 Chapter 1 1 Introduction ...

Page 12: ...T10 is preinstalled with 4th generation Intel Atom or Celeron processor The COM Express standard allows the COM Express baseboard to be designed while leaving the choice of processor till the later stages of design The ICE BT T10 provides a low power option with the full range of modern I O options The ICE BT T10 embedded module is designed for flexible integration by system developers into custom...

Page 13: ...e 1 MB cache 8 GB ICE BT T10 E38271 Intel Atom processor E3827 1 75 GHz dual core 1 MB cache 8 GB ICE BT T10 E38451 Intel Atom processor E3845 1 91 GHz quad core 2 MB cache 8 GB ICE BT T10 J19001 Intel Celeron processor J1900 2 GHz quad core 2 MB cache 8 GB ICE BT T10 N28071 Intel Celeron processor N2807 1 58 GHz dual core 2 MB cache 4 GB ICE BT T10 N29301 Intel Celeron processor N2930 1 83 GHz qu...

Page 14: ...4 GB SSD Supports analog CRT VGA DisplayPort and HDMI Supports USB 3 0 SATA 3Gb s and GbE RoHS compliant 1 4 Board Overview The on board components and connectors of the ICE BT T10 are shown in the figures below Figure 1 2 On board Components and Connectors ...

Page 15: ...ICE BT T10 COM Express Module Page 5 1 5 Dimensions The main dimensions of the ICE BT T10 are shown in the diagram below Figure 1 3 ICE BT T10 Dimensions mm ...

Page 16: ...ICE BT T10 COM Express Module Page 6 Figure 1 4 ICE BT T10 Heatsink Dimensions mm ...

Page 17: ...ICE BT T10 COM Express Module Page 7 1 6 Data Flow Figure 1 5 shows the data flow between the system chipset the CPU and other components installed on the motherboard Figure 1 5 Data Flow Diagram ...

Page 18: ...Hz dual core 1MB cache TDP 8W o Intel Atom processor E3826 1 46GHz dual core 1MB cache TDP 7W o Celeron processor J1900 2GHz quad core 2MB cache TDP 10W o Intel Celeron processor N2930 1 83GHz quad core 2MB cache TDP 7 5W o Intel Celeron processor N2807 1 58GHz dual core 2MB cache TDP 4 5W Memory 2 GB DDR3 on board memory Internal Storage 2 Kb serial I2 C bus EEPROM supports EAPI Rev 1 0 Graphics ...

Page 19: ...pansions Signal to Baseboard Three PCIe x1 I O Interfaces Signal to Baseboard Four USB 2 0 One USB 3 0 Two RS 232 TX and RX from EC HD Audio 8 bit GPIO SMBus I2 C LPC SPI Power Consumption 12V 0 43 A Vcore_12V 0 9 A 1 91 GHz Intel Atom E3845 CPU with 2 GB 1333 MHz DDR3L memory Operating Temperature 20ºC 60ºC Storage Temperature 30ºC 70ºC Operating Humidity 5 95 non condensing Dimensions 84 mm x 55...

Page 20: ...ICE BT T10 COM Express Module Page 10 Chapter 2 2 Packing List ...

Page 21: ...tatic discharge Self grounding Touch a grounded conductor every few minutes to discharge any excess static buildup Use an anti static pad When configuring any circuit board place it on an anti static mat Only handle the edges of the PCB Don t touch the surface of the motherboard Hold the motherboard by the edges when handling 2 2 Unpacking Precautions When the ICE BT T10 is unpacked please do the ...

Page 22: ...ion Contact the IEI reseller or vendor the ICE BT T10 was purchased from or contact an IEI sales representative directly by sending an email to 31sales ieiworld com The ICE BT T10 is shipped with the following components Quantity Item and Part Number Image 1 ICE BT T10 COM Express Module 1 Heatsink 1 Utility CD 1 Quick Installation Guide Table 2 1 Packing List ...

Page 23: ...ss Module Page 13 2 4 Optional Items The following are optional components which may be separately purchased Item and Part Number Image Baseboard for COM Express Type 10 modules P N ICE DB T10 R10 Table 2 2 Optional Items ...

Page 24: ...ICE BT T10 COM Express Module Page 14 Chapter 3 3 Connectors ...

Page 25: ...ut The figure below shows all the connectors Figure 3 1 Connectors Solder Side 3 1 2 Peripheral Interface Connectors The table below lists all the connectors on the ICE BT T10 Connector Type Label COM Express connector AB COM Express connector COMEXPRESS_T10_AB1 SPI Flash BIOS 6 pin wafer JSPI1 Table 3 1 Peripheral Interface Connectors ...

Page 26: ...nnector CN Location See Figure 3 2 CN Pinouts See Table 3 2 The standard COM Express connector location and pinouts are shown below Figure 3 2 COM Express Connector Location Pin No Description Pin No Description A1 GND B1 GND15 A2 GBE0_MDI3 B2 GBE0_ACT A3 GBE0_MDI3 B3 LPC_FRAME A4 GBE0_LINK100 B4 LPC_AD0 A5 GBE0_LINK1000 B5 LPC_AD1 A6 GBE0_MDI2 B6 LPC_AD2 A7 GBE0_MDI2 B7 LPC_AD3 A8 GBE0_LINK B8 RS...

Page 27: ...AT A19 SATA0_RX B19 SATA1_RX A20 SATA0_RX B20 SATA1_RX A21 GND2 B21 GND17 A22 USB_SSRX0 B22 USB_SSTX0 A23 USB_SSRX0 B23 USB_SSTX0 A24 RSVD B24 RSVD A25 RSVD B25 RSVD A26 RSVD B26 RSVD A27 BATLOW B27 WDT A28 ATA_ACT B28 RSVD A29 HDA_SYNC B29 HDA_SDIN1 A30 HDA_RST B30 HDA_SDIN0 A31 GND3 B31 GND18 A32 HDA_BITCLK B32 SPKR A33 HDA_SDOUT B33 I2C_CK A34 BIOS_DISABLE B34 I2C_DAT A35 RSVD B35 RSVD A36 RSVD...

Page 28: ...52 RSVD A53 VGA_VSYNC B53 VGA_RED A54 GPI0 B54 GPO1 A55 VGA_I2C_CK B55 VGA_GRN A56 VGA_I2C_DAT B56 VGA_BLU A57 GND6 B57 GPO2 A58 RSVD B58 RSVD A59 RSVD B59 RSVD A60 GND7 B60 GND A61 PCIE_TX2 B61 PCIE_RX2 A62 PCIE_TX2 B62 PCIE_RX2 A63 GPI1 B63 GPO3 A64 PCIE_TX1 B64 PCIE_RX1 A65 PCIE_TX1 B65 PCIE_RX1 A66 GND8 B66 WAKE0 A67 GPI2 B67 RSVD A68 PCIE_TX0 B68 PCIE_RX0 A69 PCIE_TX0 B69 PCIE_RX0 A70 GND9 B7...

Page 29: ...WM eDP A84 DDI0_AUXN eDP B84 VCC5SBY A85 GPI3 B85 VCC5SBY A86 RSVD B86 VCC5SBY A87 eDP_HPD B87 VCC5SBY A88 PCIE0_CK_REF B88 BIOS_DIS1 A89 PCIE0_CK_REF B89 DDI1_HPD A90 GND11 B90 GND24 A91 SPI_VCC B91 RSVD A92 SPI_MISO B92 RSVD A93 GPO0 B93 RSVD A94 SPI_CLK B94 RSVD A95 SPI_MOSI B95 DDI1_DDC_AUX_SEL A96 RSVD B96 RSVD A97 TYPE10 B97 SPI_CS A98 RS1_TX B98 DDI1_CTRLCLK_AUXP A99 RS1_RX B99 DDI1_CTRLDAT...

Page 30: ...10 GND26 Table 3 2 COM Express Connector Pin Definitions 3 2 2 SPI Flash Connector CN Label JSPI1 CN Type 6 pin wafer CN Location See Figure 3 3 CN Pinouts See Table 3 3 The SPI Flash connector is for flashing new BIOS onto the SPI BIOS chip Figure 3 3 SPI Flash Connector Location Pin Description 1 V1 8M_SPI_CON 2 SPI_CS 3 SPI_SO 4 SPI_CLK 5 SPI_SI 6 GND Table 3 3 SPI Flash Connector Pinouts ...

Page 31: ...ICE BT T10 COM Express Module Page 21 Chapter 4 4 Installation ...

Page 32: ...istband can help to prevent ESD from damaging the board Self grounding Before handling the board touch any grounded conducting material During the time the board is handled frequently touch any conducting materials that are connected to the ground Use an anti static pad When configuring the ICE BT T10 place it on an antic static pad This reduces the possibility of ESD damaging the ICE BT T10 Only ...

Page 33: ...from the body and helps prevent ESD damage Place the ICE BT T10 on an antistatic pad o When installing or configuring the motherboard place it on an antistatic pad This helps to prevent potential ESD damage Turn all power to the ICE BT T10 off o When working with the ICE BT T10 make sure that it is disconnected from all power supplies and that no electricity is being fed into the system Before and...

Page 34: ...he thermal pad acts as a thermal interface between the module and the heatsink The heatsink must be installed on the ICE BT T10 to maintain proper operating temperatures Make sure to maintain the heatsink temperature under 60 C in operation Follow the steps below to install the ICE BT T10 to the optional baseboard Step 1 Align the two COM Express connector on the solder side of the ICE BT T10 with...

Page 35: ...onnectors Step 2 Ensure a thermal pad is placed on the CPU of the ICE BT T10 Step 3 Place the heatsink on the ICE BT T10 aligning the retention screw holes Figure 4 2 Step 4 Secure the heatsink to the ICE BT T10 and the baseboard with the supplied retention screws Figure 4 2 ...

Page 36: ...ICE BT T10 COM Express Module Page 26 Figure 4 2 Secure the Heatsink ...

Page 37: ...ICE BT T10 COM Express Module Page 27 Chapter 5 5 BIOS ...

Page 38: ...P message appears on the screen If the message disappears before the DEL or F2 key is pressed restart the computer and try again 5 1 2 Using Setup Use the arrow keys to highlight items press ENTER to select use the PageUp and PageDown keys to change entries press F1 for help and press ESC to quit Navigation keys are shown in the following table Key Function Up arrow Move to previous item Down arro...

Page 39: ...he Help Window press ESC or the F1 key again 5 1 4 Unable to Reboot after Configuration Changes If the computer cannot boot after changes to the system configuration are made CMOS defaults Use the clear CMOS jumper described in the baseboard user manual 5 1 5 BIOS Menu Bar The menu bar on top of the BIOS screen has the following main items Main Changes the basic system configuration Advanced Chang...

Page 40: ...ocode Patch 321 BayTrial SoC B3 Stepping Memory Information Total Memory 2048 MB LPDDR3 G0P Information Intel R G0P Driver N A TXE Information Sec RC Version 00 05 00 00 TXE FW Version 01 00 02 1060 System Date Fri 01 01 2010 System Time 15 10 27 Access Level Administrator Set the Date Use Tab to switch between Date elements Select Screen Select Item Enter Select Change Opt F1 General Help F2 Prev...

Page 41: ...ty Copyright C 2013 American Megatrends Inc Main Advanced Chipset Security Boot Save Exit ACPI Settings IT8587 Super IO Configuration iWDD H W Monitor RTC Wake Settings Serial Port Console Redirection CPU Configuration IDE Configuration SDIO Configuration USB Configuration System ACPI Parameters Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defau...

Page 42: ... Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 3 ACPI Settings ACPI Sleep State S3 Suspend to RAM Use the ACPI Sleep State option to specify the sleep state the system enters when it is not being used S3 Suspend to RAM DEFAULT The caches are flushed and the CPU is powered off Power to the RAM ...

Page 43: ...mized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 4 IT8587 Super IO Configuration 5 3 2 1 Serial Port n Configuration Use the Serial Port n Configuration menu BIOS Menu 5 to configure the serial port n Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced Serial Port n Configuration Serial Port Enabled Device Settings IO 3F8h ...

Page 44: ...ddress are automatically detected IO 3F8h IRQ 4 Serial Port I O port address is 3F8h and the interrupt address is IRQ4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 3F8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 2F8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 Se...

Page 45: ...ddress are automatically detected IO 2F8h IRQ 3 Serial Port I O port address is 2F8h and the interrupt address is IRQ3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 3F8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 Serial Port I O port address is 2F8h and the interrupt address is IRQ3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 Se...

Page 46: ...6 V 5V 4 978 V 12V 11 321 V DDR 1 334 V 5VSB 4 918 V 3 3V 3 236 V 3 3VSB 3 236 V Smart Fan Mode Configuration Smart Fan Mode Select Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 6 iWDD H W Monitor PC Health Status The following system parameters an...

Page 47: ...e Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 7 Smar Fan Mode Configuration Fan 1 Smart Fan Control Auto Mode Use the Fan 1 Smart Fan Control option to configure the CPU Smart Fan Manual Mode The fan spins at the speed set in Manual by Duty Cycle settings Auto Mode DEFAULT The fan adjusts it...

Page 48: ...enabled System will wake on the date hr min sec specified Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 8 RTC Wake Settings Wake system with Fixed Time Disabled Use the Wake system with Fixed Time option to enable or disable the system wake on alar...

Page 49: ...serial port Aptio Setup Utility Copyright C 2013 American Megatrends Inc Advanced COM1 Console Redirection Disabled Console Redirection Settings COM2 Console Redirection Disabled Console Redirection Settings COM3 Pci Bus0 Dev0 Func0 Disabled Console Redirection Port Is Disabled Console Redirection Enable or Disable Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Value...

Page 50: ... ANSI DEFAULT The target terminal type is ANSI Bits per second 115200 Use the Bits per second option to specify the serial port transmission speed The speed must match the other side Long or noisy lines may require lower speeds 9600 Sets the serial port transmission speed at 9600 19200 Sets the serial port transmission speed at 19200 38400 Sets the serial port transmission speed at 38400 57600 Set...

Page 51: ...r of ones in the data bits is even Odd The parity bit is 0 if the number of ones in the data bits is odd Mark The parity bit is always 1 This option does not provide error detection Space The parity bit is always 0 This option does not provide error detection Stop Bits 1 Use the Stop Bits option to specify the number of stop bits used to indicate the end of a serial data packet Communication with ...

Page 52: ... Technology and Disabled for other OS OS not optimized for Hyper Threading Technology When Disabled only one thread per enabled core is enabled Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 10 CPU Configuration The CPU Configuration menu BIOS Menu ...

Page 53: ...ULT Enable all cores in the processor package 1 Enable one core in the processor package Intel Virtualization Technology Enabled Use the Intel Virtualization Technology option to enable or disable virtualization on the system When combined with third party software Intel Virtualization technology allows several OSs to run on the same system at the same time Disabled Disables Intel Virtualization T...

Page 54: ...ATA Device Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 11 SATA Configuration Serial ATA SATA Enabled Use the Serial ATA SATA option to enable or disable the SATA controller Enabled DEFAULT Enable SATA controller Disabled Disable SATA controller S...

Page 55: ...ption Access SD device in DMA mode PIO Option Access SD device in PIO mode Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 12 USB Configuration SDIO Access Mode Auto Use the SDIO Access Mode BIOS to select SD device access modes Auto DEFAULT If contr...

Page 56: ... General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 13 USB Configuration USB Devices The USB Devices field lists the USB devices that are enabled on the system Legacy USB Support Enabled Use the Legacy USB Support BIOS option to enable USB mouse and USB keyboard support Normally if this option is not enab...

Page 57: ...wrong values for the Chipset BIOS selections in the Chipset BIOS menu may cause the system to malfunction Aptio Setup Utility Copyright C 2013 American Megatrends Inc Main Advanced Chipset Security Boot Save Exit North Bridge South Bridge North Bridge Parameters Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version ...

Page 58: ...al Memory 2048 MB LPDDR3 Memory Slot0 2048 MB LPDDR3 Max TOLUD Dynamic Config Intel IGD Settings Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 15 North Bridge Configuration Max TOLUD Dynamic Use the Max TOLUD option to select the maximum value of T...

Page 59: ...1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 16 Graphics Configuration Primary Display Auto Use the Primary Display option to select the primary graphics controller the system uses The following options are available Auto IGD Default PCIe SG DVMT Pre Allocated 256M Use the DVMT Pre Allocated optio...

Page 60: ...graphic memory size used by the internal graphic device The following options are available 128M 256M Default MAX Primary IGFX Boot Display VBIOS Default Use the Primary IGFX Boot Display option to select the display device used by the system when it boots Configuration options are listed below VBIOS Default DEFAULT CRT EFP LFP EFP3 EFP2 LFP2 ...

Page 61: ...neral Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 17 PCH IO Configuration Restore AC Power Loss Last State Use the Restore AC Power Loss BIOS option to specify what state the system returns to if there is a sudden loss of power to the system Power Off The system remains turned off Power On The system turns...

Page 62: ...pe of the PCI Express or PCIe Mini slots Aptio Setup Utility Copyright C 2013 American Megatrends Inc Chipset PCI Express Configuration PCI Express Port 2 Enabled Speed Auto Enable or Disable the PCI Express Port 2 in the Chipset Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 Americ...

Page 63: ...ly asked for when entering Setup If ONLY the User s password is set then this is a power on password and must be entered to boot or enter Setup In Setup the User will have Administrator rights The password length must be in the following range Minimum length 3 Maximum length 20 Administrator Password User Password Set Setup Administrator Password Select Screen Select Item Enter Select Change Opt F...

Page 64: ...xit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 20 Boot Bootup NumLock State On Use the Bootup NumLock State BIOS option to specify if the number lock setting must be modified during boot up On DEFAULT Allows the Number Lock on the keyboard to be enabled automatically when the computer system boots up This allows the immediate use of the 10 key numeric keypad loca...

Page 65: ...ices Disabled DEFAULT Disables to boot from the UEFI devices OS Selection Windows 8 X Use the OS Selection option to select an operating system for the system Windows 8 X DEFAULT Android Windows 7 Launch PXE OpROM Disabled Use the Launch PXE OpROM option to enable or disable boot option for legacy network devices Disabled DEFAULT Ignore all PXE Option ROMs Enabled Load PXE Option ROMs Option ROM M...

Page 66: ...nges Select Screen Select Item Enter Select Change Opt F1 General Help F2 Previous Values F3 Optimized Defaults F4 Save Exit ESC Exit Version 2 16 1242 Copyright C 2013 American Megatrends Inc BIOS Menu 21 Save Exit Discard Changes and Exit Use the Discard Changes and Exit option to exit the system without saving the changes made to the BIOS configuration setup program Save Changes and Reset Use t...

Page 67: ...lt values for each of the parameters on the Setup menus F3 key can be used for this operation Save as User Defaults Use the Save as User Defaults option to save the changes done so far as user defaults Restore User Defaults Use the Restore User Defaults option to restore the user defaults to all the setup options ...

Page 68: ...ICE BT T10 COM Express Module Page 58 6 Software Drivers Chapter 6 ...

Page 69: ...updates The following drivers can be installed on the system Chipset Graphics LAN Installation instructions are given below 6 2 Starting the Driver Program To access the driver installation programs please do the following Step 1 Insert the CD that came with the system into a CD drive connected to the system NOTE If the installation program doesn t start automatically Click Start Computer CD Drive...

Page 70: ...ICE BT T10 COM Express Module Page 60 Figure 6 1 Start Up Screen Step 3 Click ICE BT T10 Step 4 The list of drivers in Figure 6 2 appears Figure 6 2 Drivers ...

Page 71: ...lder which corresponds to the operating system NOTE The remainder of this installation assumes Windows 8 as the operating system Step 3 Locate the setup file infinst_autol_9 4 4 1006 exe and double click on it Step 4 When the setup files are completely extracted the Welcome Screen in Figure 6 3 appears Click Next to continue Figure 6 3 Chipset Driver Welcome Screen Step 5 The License Agreement in ...

Page 72: ...odule Page 62 Step 6 Click Yes to accept the agreement and continue Figure 6 4 Chipset Driver License Agreement Step 7 The Read Me file in Figure 6 5 appears Step 8 Click Next to continue Figure 6 5 Chipset Driver Read Me File ...

Page 73: ...6 6 Step 10 Once the Setup Operations are complete click Next to continue Figure 6 6 Chipset Driver Setup Operations Step 11 The Finish screen in Figure 6 7 appears Step 12 Select Yes I want to restart this computer now and click Finish Step 0 Figure 6 7 Chipset Driver Installation Finish Screen ...

Page 74: ...system Step 3 Unzip the file called 15 33 7 3366 zip and then locate the setup file and double click on it to start the installation If a 64 bit operating system is installed please unzip the 15 33 7 64 336 zip file to install the graphics driver NOTE To install graphics driver on a 32 bit Windows 7 system unzip INTEL_EMGD WIN7_PC_VERSION_36_15_0_1064 7Z To install graphics driver on a 64 bit Wind...

Page 75: ... Graphics Driver License Agreement Step 6 The License Agreement in Figure 6 9 appears Step 7 Click Yes to accept the agreement and continue Figure 6 9 Graphics Driver Read Me File Step 8 The Read Me file in Figure 6 10 appears Click Next to continue ...

Page 76: ... 9 Setup Operations are performed as shown in Figure 6 11 Step 10 Once the Setup Operations are complete click Next to continue Figure 6 11 Graphics Driver Installation Finish Screen Step 11 The system starts installing the Graphics Driver Step 12 The Finish screen in Figure 6 12 appears ...

Page 77: ...tart this computer now and click Finish Step 0 Figure 6 12 Graphics Driver Installation Finish Screen 6 5 LAN Driver Installation To install the LAN driver please do the following Step 1 Right click the Computer button from the start menu and select Properties Figure 6 13 ...

Page 78: ...T10 COM Express Module Page 68 Figure 6 13 Windows Control Panel Step 2 The system control panel window in Figure 6 14 appears Step 3 Click the Device Manager link Figure 6 14 Figure 6 14 System Control Panel ...

Page 79: ...s appears Figure 6 15 Step 5 Right click the Ethernet Controller that has question marks next to it this means Windows does not recognize the device Step 6 Select Update Driver Software Figure 6 15 Device Manager List Step 7 The Update Driver Software Window appears Figure 6 16 ...

Page 80: ... Window Step 8 Select Browse my computer for driver software and click NEXT to continue Step 9 Click Browse to select X 2 LAN Intel directory in the Locate File window where X is the system CD drive Figure 6 17 Figure 6 17 Locate Driver Files Step 10 Click NEXT to continue ...

Page 81: ...allation is performed When the Finish screen appears click Close to exit Step 12 Right click the other Ethernet controller that has question marks next to it as shown in Figure 6 15 Repeat Step 6 Step 11 to install the second Ethernet controller driver Step 0 ...

Page 82: ...ICE BT T10 COM Express Module Page 72 Appendix A A Regulatory Compliance ...

Page 83: ...interference that may cause undesired operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and...

Page 84: ...ICE BT T10 COM Express Module Page 74 Appendix B B BIOS Options ...

Page 85: ... start PWM 37 Auto mode fan slope PWM 38 Wake system with Fixed Time Disabled 38 Console Redirection Disabled 39 Terminal Type ANSI 40 Bits per second 115200 40 Data Bits 8 40 Parity None 41 Stop Bits 1 41 Active Processor Cores All 43 Intel Virtualization Technology Enabled 43 EIST Enabled 43 Serial ATA SATA Enabled 44 SATA Mode Selection IDE 44 SDIO Access Mode Auto 45 USB Devices 46 Legacy USB ...

Page 86: ...r Password 53 User Password 53 Bootup NumLock State On 54 Quiet Boot Enabled 55 UEFI Boot Disabled 55 OS Selection Windows 8 X 55 Launch PXE OpROM Disabled 55 Option ROM Messages Force BIOS 55 Discard Changes and Exit 56 Save Changes and Reset 56 Discard Changes and Reset 56 Restore Defaults 57 Save as User Defaults 57 Restore User Defaults 57 ...

Page 87: ...ICE BT T10 COM Express Module Page 77 Appendix C C Terminology ...

Page 88: ... low amplitude signal represents a binary 0 while a high amplitude signal represents a binary 1 BIOS The Basic Input Output System BIOS is firmware that is first run when the computer is turned on and can be configured by the end user CODEC The Compressor Decompressor CODEC encodes and decodes digital audio data on the system CMOS Complimentary metal oxide conductor is an integrated circuit used i...

Page 89: ...cation software changes the bus to core frequency ratio and the processor core voltage FSB The Front Side Bus FSB is the bi directional communication channel between the processor and the Northbridge chipset GbE Gigabit Ethernet GbE is an Ethernet version that transfers data at 1 0 Gbps and complies with the IEEE 802 3 2005 standard GPIO General purpose input HDD Hard disk drive HDD is a type of m...

Page 90: ...bus has transfer speeds up to 1 5 Gbps and the SATA II bus has data transfer speeds of up to 3 0 Gbps S M A R T Self Monitoring Analysis and Reporting Technology S M A R T refers to automatic status checking technology implemented on hard disk drives UART Universal Asynchronous Receiver transmitter UART is responsible for asynchronous communications on the system and manages the system s serial co...

Page 91: ...ICE BT T10 COM Express Module Page 81 Appendix D D Watchdog Timer ...

Page 92: ...l INT 15H is used to control the Watchdog Timer INT 15H AH 6FH Sub function AL 2 Sets the Watchdog Timer s period BL Time out value Its unit second is dependent on the item Watchdog Timer unit select in CMOS setup Table D 1 AH 6FH Sub function Call sub function 2 to set the time out period of Watchdog Timer first If the time out value is not zero the Watchdog Timer starts counting down When the ti...

Page 93: ...the system resets EXAMPLE PROGRAM INITIAL TIMER PERIOD COUNTER W_LOOP MOV AX 6F02H setting the time out value MOV BL 30 time out value is 48 seconds INT 15H ADD THE APPLICATION PROGRAM HERE CMP EXIT_AP 1 is the application over JNE W_LOOP No restart the application MOV AX 6F02H disable Watchdog Timer MOV BL 0 INT 15H EXIT ...

Page 94: ...ICE BT T10 COM Express Module Page 84 Appendix E E Hazardous Materials Disclosure ...

Page 95: ... the presences of small quantities of certain materials in the product and is applicable to China RoHS only A label will be placed on each product to indicate the estimated Environmentally Friendly Use Period EFUP This is an estimate of the number of years that these substances would not leak out or undergo abrupt change This product may contain replaceable sub assemblies components which have a s...

Page 96: ...rcuit Board O O O O O O Metal Fasteners O O O O O O Cable Assembly O O O O O O Fan Assembly O O O O O O Power Supply Assemblies O O O O O O Battery O O O O O O O This toxic or hazardous substance is contained in all of the homogeneous materials for the part is below the limit requirement in SJ T11363 2006 X This toxic or hazardous substance is contained in at least one of the homogeneous materials...

Page 97: ...品可能包含有较短的环境友好使用期限的可替换元件 像是电池或灯管 这些元 件将会单独标示出来 有毒有害物质或元素 部件名称 铅 Pb 汞 Hg 镉 Cd 六价铬 CR VI 多溴联苯 PBB 多溴二苯 醚 PBDE 壳体 O O O O O O 显示 O O O O O O 印刷电路板 O O O O O O 金属螺帽 O O O O O O 电缆组装 O O O O O O 风扇组装 O O O O O O 电力供应组装 O O O O O O 电池 O O O O O O O 表示该有毒有害物质在该部件所有物质材料中的含量均在 SJ T11363 2006 标准规定的限量要求以下 X 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ T11363 2006 标准规定的限量要求 ...