AFL3-W19A-AL Panel PC
Page 115
NOTE:
The following discussion applies to DOS. Contact IEI support or visit the IEI
website for drivers for other operating systems.
The Watchdog Timer is a hardware-based timer that attempts to restart the system when it
stops working. The system may stop working because of external EMI or software bugs.
The Watchdog Timer ensures that standalone systems like ATMs will automatically
attempt to restart in the case of system problems.
A BIOS function call (INT 15H) is used to control the Watchdog Timer.
INT 15H:
AH – 6FH Sub-function:
AL – 2:
Sets the Watchdog Timer’s period.
BL:
Time-out value (Its unit-second is dependent on the item “Watchdog
Timer unit select” in CMOS setup).
Table D-1: AH-6FH Sub-function
Call sub-function 2 to set the time-out period of Watchdog Timer first. If the time-out value
is not zero, the Watchdog Timer starts counting down. When the timer value reaches zero,
the system resets. To ensure that this reset condition does not occur, calling sub-function
2 must periodically refresh the Watchdog Timer. However, the watchdog timer is disabled
if the time-out value is set to zero.
A tolerance of at least 10% must be maintained to avoid unknown routines within the
operating system (DOS), such as disk I/O that can be very time-consuming.
Summary of Contents for AFL3-W19A-AL
Page 16: ......
Page 17: ...AFL3 W19A AL Panel PC Page 1 1 Introduction Chapter 1 ...
Page 27: ...AFL3 W19A AL Panel PC Page 11 2 Unpacking Chapter 2 ...
Page 32: ...AFL3 W19A AL Panel PC Page 16 3 Installation Chapter 3 ...
Page 59: ...AFL3 W19A AL Panel PC Page 43 4 BIOS Setup Chapter 4 ...
Page 93: ...AFL3 W19A AL Panel PC Page 77 5 System Maintenance Chapter 5 ...
Page 97: ...AFL3 W19A AL Panel PC Page 81 6 Interface Connectors Chapter 6 ...
Page 115: ...AFL3 W19A AL Panel PC Page 99 Appendix A A Regulatory Compliance ...
Page 121: ...AFL3 W19A AL Panel PC Page 105 B Safety Precautions Appendix B ...
Page 127: ...AFL3 W19A AL Panel PC Page 111 C BIOS Menu Options Appendix C ...
Page 130: ...AFL3 W19A AL Panel PC Page 114 Appendix D D Watchdog Timer ...
Page 133: ...AFL3 W19A AL Panel PC Page 117 Appendix E E Hazardous Materials Disclosure ...