B5U033000E
Page 20 of 54
Parameter
Description
Range
Default
Q Initial
The minimum allowed Q value in dynamic Q
algorithm mode.
0 … 15
0
Q Final
The maximum allowed Q value in dynamic Q
algorithm mode.
0 … 15
4
Q Adjust
Rounds
The maximum Q adjust rounds in dynamic Q
algorithm mode.
0 … 5
3
Inventory
Cycles
The inventory cycles in inventory command.
0 … 5
3
Search Mode
How the reader singulates (select) tags in
‘continuous’ mode.
Dual Target
Single Target
Dual Target
Session
The session used as defined in EPC Class 1
Generation 2 protocol.
S0
S1
S2
S3
S0
Target
The target used as defined in EPC Class 1
Generation 2 protocol.
A
B
A
EPC size
The size of the recognized EPC in bytes. 0 means
all EPC sizes,
0 … 62
0
ReadAfterDete
ct Activation
Activation of the ReadAfterDetect mode in
‘continuous’ mode.
Note that this parameter become effective
only after a reboot of the reader.
None
TID
Custom
None
ReadAfterDete
ct Password
The password to be used to access to tag
’s
memory in ReadAfterDetect mode (Inventory
Mode = Standard Single/Multi Tag with Custom
Info). Use a ‘0’ password if the access password is
not requested.
Note that this parameter become effective
only after a reboot of the reader.
0x00 0x00
0x00 0x00
…
0xFF 0xFF
0xFF 0xFF
0x00 0x00
0x00 0x00
ReadAfterDete
ct Bank
The tag’s memory bank to access in
ReadAfterDetect mode (Inventory Mode =
Standard Single/Multi Tag with Custom Info).
Note that this parameter become effective
only after a reboot of the reader.
Reserved
TID
EPC
User
Reserved
ReadAfterDete
ct Address
The tag’s memory start address to access in the
specified memory bank in ReadAfterDetect mode
(Inventory Mode = Standard Single/Multi Tag with
Custom Info).
Note that this parameter become effective
only after a reboot of the reader.
0x00 0x00
0x00 0x00
…
0xFF 0xFF
0xFF 0xFF
0x00 0x00
0x00 0x00
ReadAfterDete
ct Length
The number of tag’s memory blocks (2
-bytes
length) to access in the specified memory bank in
ReadAfterDetect mode (Inventory Mode =
0 … 255
0