1. Important Safety Instructions 

 

When using your 

Proximity Card Reader

, basic safety precautions should always be followed to 

reduce the risk of fire, electrical shock, and injury to persons. In addition, the following should also be 
followed: 

 
1. Read and understand all instructions.   
2. Follow all warnings and instructions marked on the product. 
3. 

Do not

 use liquid cleaners or aerosol cleaners. Use a damp cloth for cleaning. If necessary, use mild 

soap. 

4. 

Do not

 use this product near water, such as bath-tub, wash bowl, kitchen sink, laundry tub, in a wet 

basement, or swimming pool. 

5. This product should be operated only from the type of power source indicated on the marking label. If 

you are not sure of the type of power supplied to your installation site, consult your dealer or local 
power company. 

6. 

Never

 push objects of any kind into this product or through the cabinet slots as they may touch 

voltage points or short out parts that could result in fire or electric shock. Never spill liquid of any kind 
on the product. 

7. To reduce the risk of electric shock, do not disassemble this product by yourself, but take it to 

qualified service whenever service or repair is required. Opening or removing the covers may expose 
you to dangerous voltages or other risks. Also, incorrect reassembly can cause electric shock when 
the unit is subsequently used. 

8. 

Unplug

 this product from the Direct Current (DC) power source and refer to qualified service 

personnel under these conditions: 

a.

 

When the power supply cord or plug is damaged or frayed. 

b.

 

If liquid has been spilled on the product. 

c.

 

If the product does not operate normally after following the operating instructions in this manual. 

Adjust only those controls that are covered by the operating instructions in this manual. Improper 
adjustment of other controls that are not covered by this manual may damage the unit and will 
often require extensive work by a qualified technician to restore normal operation. 

d. If the product exhibits a distinct change in performance.

 

 

2. General 

 
The 

Star RF TINY

 is an elegant looking and an attractive 4" read range proximity reader which can be 

mounted to metal door frame (mullion) or any flat wall surface. The 

Star RF TINY

 uses the same 

electronics module in epoxy potting that ensures you successful operation even in harsh environments. 
The different bezels allow you to interchange the bezel for different applications or wall conditions. 

 
 

Summary of Contents for Star RF TINY

Page 1: ...User s Manual Proximity Card Reader ...

Page 2: ...2 General 3 3 Features 4 4 Specification 4 5 Identifying Supplied Parts 5 4 Installation 5 5 Wire Color Table of the RF TINY 6 6 Wire Connection to Controller 6 7 Operation 7 8 FCC Registration Information 8 9 Warranty Policy and Limitation of Liability 9 ...

Page 3: ...e it to qualified service whenever service or repair is required Opening or removing the covers may expose you to dangerous voltages or other risks Also incorrect reassembly can cause electric shock when the unit is subsequently used 8 Unplug this product from the Direct Current DC power source and refer to qualified service personnel under these conditions a When the power supply cord or plug is ...

Page 4: ...d Party Controllers 4 Specification Model RF TINY CPU 8bit Microprocessor IDK50 IMC125 Up to 2 inches 5 cm IDC80 Up to 2 8 inches 7 cm Passive Type IDC170 Up to 4 inches 10 cm Read Range Active Type IDA150 IDA200 Compatible Reading Time Card 30ms Power Current DC 12V Max 180mA Input Port 2 Ports External LED Control External Buzzer Control Output Format 26bit Wiegand Default RS232 and ABA Track II...

Page 5: ...Bolt 2ea 2ea 2ea 4 Installation 4 1 Mullion Wall Mount Drill two 3mm holes 2 72 69mm apart in vertical and drill one 1 2 hole for the controller cable 1 36 34 5mm apart from the top hole 4 2 Put reader cable into the center hole and install the reader module by using two 3 20 screws 4 3 Put bezel into the reader module then push bezel until you hear the locking sound ...

Page 6: ...k Out White Buzzer Control In Blue LED Control In Yellow RS232 TX Purple Not Connect Brown Not Connect Gray Please cut out tail connector before installation Red Black Orange Green White Purple Blue Yellow Brown Gray Access Controller Main Power 12V Power Ground GND ABA Track II CP Out Wiegand Data 0 Out ABA Track II Data Out Wiegand Data1 Out ABA Track II Clock Out RS232 TX Buzzer Control In LED ...

Page 7: ... LED Control Input Yellow wire to GND The next LED displays green color that indicates in standby reader If you make RF card present the LED of product changes color to red simultaneously And then it turns green again for next reading 7 4 Buzzer Control When the product reads RF card only one beeping sounds in normal operating mode Whether the access is granted or denied the product sounds more be...

Page 8: ...ant to Part 15 of the FCC Rules These limits are designed to this equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radi...

Page 9: ... property is located where this product will be used it would be extremely difficult to determine the actual damages that may result from a failure of the product to perform as anticipated and the low price of this product is based upon the nature of the product provided and the limited liability that IDTECK assumes IDTECK IS NOT RESPONSIBLE FOR ANY PERSONAL INJURY PROPERTY DAMAGE OR LOSS DIRECT S...

Page 10: ...ation Code 1 Company Name 2 Model Name 3 Serial No 4 Original Invoice No 5 Distributor 6 Purchasing Date 7 RMA Request Date Please check your problems Card Reading Power Keypad Communication Relay LCD LED Buzzer Registration Others IDTECK RMA Center 3F 10 10 1 10 2 Dodang Dong Weonmi Gu Bucheon Si Gyeonggi Do 157 030 Korea Telephone 82 2 2659 0055 HQ 82 32 671 5642 RMA Center Fax 82 2 2659 0086 HQ...

Page 11: ...11 MEMO ...

Page 12: ...TINYHE2X The specifications contained in this manual are subject to change without notice at any time 5F Ace Techno Tower B D 684 1 Deungchon Dong Gangseo Gu Seoul 157 030 Korea Tel 82 2 2659 0055 Fax 82 2 2659 0086 E mail webmaster idteck com ...

Reviews: