Copyright © 2010-2020, International Technologies & Systems Corporation. All rights reserved.
Page 15 of 76
User Manual, SecureHead USB and UART Interface
“6” Require Track 2 & Track 3
“7” Require All Three Tracks
“8” Any Track 1 & 2
“9” Any Track 2 & 3
Note: If any of the required multiple tracks fail to read for any reason, no data for any track will be
sent.
3.8.2.
Track Separator Selection
This option allows the user to select the character to be used to separate data decoded by a multiple-
track reader.
<STX><S><17h><01h><Track_Separator><ETX><CheckSum>
<Track_Separator> is one ASCII Character.
The default value is
CR,
0h means no track separator.
3.8.3.
Start/End Sentinel and Track 2 Account Number Only
The SecureHead can be set to either send, or not send, the Start/End sentinel, and to send either the
Track 2 account number only, or all the encoded data on Track 2. (The Track 2 account number setting
doesn’t affect the output of Track 1 and Track 3.)
<STX><S><19h><01h><SendOption><ETX><CheckSum>
SendOption:
“0” Don’t send start/end sentinel and send all data on Track 2
“1” Send start/end sentinel and send all data on Track 2
“2” Don’t send start/end sentinel and send account # on Track 2
“3” Send start/end sentinel and send account number on Track 2
3.9.
Security Settings
3.9.1.
Select Key Management Type
<STX><S><58h><01h><Key Management Type><ETX><CheckSum>
Key Management Type:
“0” Fix key management
“1” DUKPT Key management
3.9.2.
External Authenticate Command (Fixed Key Only)
Before a security related command is executed, an authentication process is required to make sure the
device key used is correct. For example, authentication is needed whenever the encryption is enabled/