Appendix A Setting Parameters and Values
Following is a table of default setting and available settings (value within parentheses) for each
function ID.
Function ID Hex Description
Default
Setting
Description
HTypeID*
10
Terminal
Type
'0'
(‘0’~’2’,'4'~'6'
)
PC/AT, Scan Code Set 2,
1, 3, PC/AT with external
Keyboard and PC/AT
without External
Keyboard
u
BeepID
11
Beep Setting ‘2’ (‘0’~’4’)
Beep volume high
and frequency high
ChaDelayID
*
12
Character
Delay
‘0’ (‘0’~’5’)
2 ms inter-character delay k
TrackSelectI
D
13
Track
Selection
‘0’ (‘0’~’9’)
Any Track 0-any; 1-7—bit
1 tk1, bit 2 tk2; bit 3 tk3.
‘8’—tk1-2; ‘9’ tk2-3
PollingInterv
alID
14
Polling
Interval
1 (1 ~ 255)
USB HID Polling Interval u
DataFmtID
15
Data Output
Format
‘0’ (‘0’~’2’)
ID TECH Format;
-
FmtOptionID 16
UIC, Mag-
Tek
H’59’
Refer to MiniMag RS232
User’s Manual
-
TrackSepID 17
Track
Separator
CR/Enter
0 for Port
Powered IV
CR for RS232, Enter for
KB any character
supported except 00 which
means none.
SendOptionI
D
19
Send Option
‘1’ (‘0’~’F’)
‘5’ for Port
Powered IV
Sentinel and Account
number control
MSRReading
ID
1A
MSR Reading ‘1’ (‘0’~’2’)
Enable MSR Reading ‘0’
MSR disable; ‘2’ Buffer
Mode
DTEnableSe
ndID*
1B
DT Enable
Send
‘0’(‘0’,’1’,’3’) Data Editing Control
-
DecodingMet
hodID
1D
Decoding
Direction
‘1’ (‘0’~’3’)
Decoding in both
direction; ‘0’ Raw data ‘2’
forward ‘3’ reverse
ReviewID
1F
Review All
Settings
None
TerminatorI
21
Terminator
CR/Enter
CR for RS232, Enter for