2.5

 

Connecting

 

to

 

the

 

Data

 

Port

 

The Kiosk III has two data connections options: USB through the USB connector and RS-232 
through the 14-pin Molex connector. 
 

 

 
 
The USB port uses a standard USB connector and pinouts. The RS-232 port has the following 
pinouts. 
 

Pin  Description 

Pin  

Description 

Power ground 

+7.5v to 45VDC  

Power ground 

+7.5v to 45VDC 

5 No 

connection 

6  Reserved

 

7 Reserved 

8  Reserved 

9 Signal 

ground 

10  Signal 

ground 

11 

RS-232 Tx 

12 

RS-232 Rx 

13 No 

connection 

14  Reserved 

 
To build your own RS-232 cable, use Molex female connector part number 0511101451 with 50394-
series crimps (see 

www.molex.com

 for more information). Pin 1 is indicated by a triangle (diagram is 

socket-side view of female connector). If you are powering the Kiosk III from this connector, wire the 
two power pins (pins 2 and 4) together and the two power ground pins together (pins 1 and 3). 
 
 

 

 

USB Port 

RS-232 Port

Summary of Contents for Kiosk III

Page 1: ...User Manual Kiosk III 80136500 001 Copyright...

Page 2: ...recorded or any other method or translated into another language or language form without the express written consent of ID TECH ID TECH is a registered trademark of International Technologies and Sy...

Page 3: ...adio TV technician for help Changes or modifications to the ViVOpay Kiosk III not expressly approved by ViVOtech could void the user s authority to operate the ViVOpay Kiosk III IC Compliance Warning...

Page 4: ...osk III Controller 11 2 3 1 Mounting the ViVOpay Kiosk III Controller Using Screws 11 2 3 2 Mounting the ViVOpay Kiosk III Controller Using Mounting Tape 12 2 4 Connecting to Power 12 2 5 Connecting t...

Page 5: ...can besupplied via a single cable toreducing the effort and complexity of installation 1 1 Features Supports ISO 14443 Type A Type B and optional Type C Felica Supports ISO 18092 with protocol stacks...

Page 6: ...O 18092 Typical Read Range 4 6 cm 1 5 to 2 3 inches Physical Controller Height 105 mm 4 13 inches Width 76 2 mm 3 00 inches Depth 22 5 mm 0 88 inches Square Bezel Antenna Height 75 mm 2 95 inches Widt...

Page 7: ...Temperature 10 C to 50 C 14 F to 122 F duration 3 months Transit 40 C to 60 C 40 F to 160 F duration 1 week Operating Humidity 5 to 90 non condensing Storage Humidity 10 to 90 non condensing duration...

Page 8: ...fy that you have the following hardware for the installation of the ViVOpayKiosk III ViVOpay Kiosk III Controller ViVOpay Kiosk III Antenna either square or angle bezel Antenna LED power and data cabl...

Page 9: ...locate and mark the four 4 4mm 0 173 inch mounting holes 2 Using the Drill Template locate and mark the two 14 0 mm 0 551 inches access holes used for connecting the antenna power and the LED power a...

Page 10: ...kiosk Make sure to tighten the nuts securely so that the ViVOpay Kiosk III does not move on the outside surface of the kiosk If you are installing the Angle Bezel Antenna tighten the nuts to 5 7 in l...

Page 11: ...llation 2 3 Mounting the ViVOpay Kiosk III Controller Note The ViVOpay Kiosk III Controller must be mounted within 1 meter of the antenna If the antenna is mounted of a surface that opens such as a do...

Page 12: ...VOpay Kiosk III Controller Using Mounting Tape 1 Position the ViVOpay Kiosk III Controller on the interior of the kiosk making sure that there is sufficient room for the antenna mounting surface to be...

Page 13: ...er ground 4 7 5v to 45VDC 5 No connection 6 Reserved 7 Reserved 8 Reserved 9 Signal ground 10 Signal ground 11 RS 232 Tx 12 RS 232 Rx 13 No connection 14 Reserved To build your own RS 232 cable use Mo...

Page 14: ...has been entered on the kiosk control panel the customer should present their card fob phone in close proximity so that maximum surface area is parallel to the antenna A single beep and all four LEDs...

Page 15: ...erference come from A Radio frequency interference RFI can originate from a wide number of sources at the point of sale POS Some examples of sources of RF energy and RF interference include AM FM radi...

Page 16: ...t polarity is observed For more information refer to the Input Voltage under the Electrical specification section Replace the ViVOpay Kiosk III Reading Cards Fobs Phones LEDs do not light and beeper i...

Page 17: ...e The Kiosk III can be upgraded using either the serial or USB interfaces 6 1 Preparation To update the new firmware you will need PC with available serial or USB port Kiosk III with a serial data cab...

Page 18: ...of 18 6 Press the button Load to load the firmware on the reader the progress will be displayed 7 Disconnect power and the serial dongle if connected 8 Connect power to the Kiosk III and connect the s...

Reviews: