7
©2019 Integrated Device Technology, Inc.
July 8, 2019
Microclock
®
5X1503/5L1503 Family Development Kit User Guide
10. Once “Burn” is clicked, a dialog of confirmation will appear verifying if the development kit has connected with user PC for OTP
programming. Click “Yes” to proceed with the OTP burn.
Figure 8. Connection Confirmation Window
11. If the OTP burn process is successful, a dialog window with “Success” will appear indicating that the process is completed and the part
has been burnt based on the configuration.
Figure 9. Success Dialog Window
JP2 on MicroClock socket board provides a select function for configuration programming to either the evaluation part or blank parts in
socket or on an evaluation board. To program OTP on a blank part in the socket or an evaluation board, ensure to un-plug the jumper on
JP2 (default jumper sets to be plugged). See
.
Figure 10. Jumper Setup
Figure 11. Connection between Socket Board and Evaluation Board