background image

Ezi4 Alarm Panel  700-497-02A  Issued April 2012   

 

 

 

 

 

91 Escom Road  •  New Germany • 3610 • South Africa • P O Box 738 • New Germany • 3620 • South Africa 

Tel: +27 (0)31 705 1373  

 Fax: +27 (0)31 705 4445 

 e-mail: [email protected] 

  www.inhep.com 

 

INHEP ELECTRONICS HOLDINGS (Pty) Ltd 

Reg. No. 2007/002578/07

 

 

Installation and Wiring 

16VAC

AUX12V

ZONES

SIREN STROBE PGM

Arm 1

2

3

4

+

-

+

-

-

-

-

+

NO C

1

2

TAMPER

Ezi4 Alarm Panel

1A

4A

4A

12V Sealed Lead

Acid Battery

+

-

To Any ‘-’ Terminal

To Communicator Input

End of Line Terminated

Zone Circuits

3K3

ZONE
INPUT

‘-’ Terminal

3K3

ZONE

INPUT

‘-’ Terminal

3K3

ZONE

INPUT

‘-’ Terminal

3K3

ZONE

INPUT

‘-’ Terminal

Normally Closed Contact

with 3K3 Terminating

Resistor

Normally Open Contact

with 3K3 Terminating

Resistor

Normally Open Contact

and Normally Closed Contact

with 3K3 terminating

Resistor

3K3 Resistor Terminating

an Unused Zone

Typical EOL Zone Circuits

Transformer

Secondary: 16Vac

Primary: 230Vac/50Hz

16VA

Black

Red

Figure 1: Ezi4 Connection Diagram  

 

 

Power Supply 

 
The  Ezi4  Alarm  panel  has  a  single  linear  regulator  onboard  that  both  charges  a 
battery and supplies power to auxiliary power supply terminals.  

 

Summary of Contents for Ezi4

Page 1: ...IDS Ezi4 Alarm Panel Installer Manual SOUTH AFRICA S LEADING MANUFACTURER AND DISTRIBUTOR OF ELECTRONIC SECURITY PRODUCTS ...

Page 2: ...ou years of problem free security The Ezi4 Alarm Panel is designed for small simple low cost installations with limited monitoring requirements It is easy to install and requires no programming to operate It is ideally suited to novice and DIY installers Zone Status information is displayed on five light emitting diodes mounted on the lid of the panel The panel also includes the following 1 x Arm ...

Page 3: ...or Input End of Line Terminated Zone Circuits 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal Normally Closed Contact with 3K3 Terminating Resistor Normally Open Contact with 3K3 Terminating Resistor Normally Open Contact and Normally Closed Contact with 3K3 terminating Resistor 3K3 Resistor Terminating an Unused Zone Typical EOL Zone Circuits Transf...

Page 4: ...ipherals are connected and what battery is used The battery must be connected to the Red Positive and Black Negative battery leads on the panel as shown The panel is polarity protected via a 1A fastblow fuse The auxiliary power supply on the Ezi4 alarm panel is used to supply power to any peripheral hardware passive infra red detectors remote receivers etc that connects to the panel It is labelled...

Page 5: ...nd is labelled Tamper reference Fig 1 A normally closed switch or contact must be connected to this input in order to operate correctly If unused ensure that a jumper is placed across the contact Failure to add a jumper across this output will prevent the panel from arming This is indicated via the power LED blinking at a faster rate of four times in on second versus once per second in a normal st...

Page 6: ...ate If the output is OFF the panel is in the disarmed state PGM Outputs 2 When a new Alarm condition is generated PGM 2 will turn on momentarily for 1 second This output is designed to link the Ezi4 Alarm Panel to either a communicator input or to link the Ezi4 Alarm Panel to another panel Display Five Light emitting diodes LEDs are mounted on the lid of the alarm panel as shown in figure 4 below ...

Page 7: ...ll flash once per second If the tamper input open the power led will flash four times per second Violating a Zone A zone is considered violated by the panel if it is shorted to or opened for a period exceeding 300mS This makes the Ezi4 alarm panel zone input suitable for most sensor types with the exception being vibration switches Arming the Panel The Ezi4 alarm panel will enter the armed state i...

Page 8: ...water damage fire damage or damage arising out of abuse and improper application of the equipment NOTE Wherever possible return only the PCB to Inhep Electronics Holdings service centres DO NOT return the enclosure The IDS Ezi4 Alarm Panel is a product of IDS Inhep Digital Security and is manufactured by Inhep Electronics Holdings Pty Ltd WARNING For safety reasons only connect equipment with a te...

Reviews: