background image

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Warranty 

  

Inhep  Electronics  Holdings  (Pty)  Ltd  guarantees  all  IDS  Control 
Panels  against  defective  parts  and  workmanship  for  24  months 
from  date  of  purchase.    Inhep  Electronics  Holdings  shall,  at  it’s 
option, repair or replace the defective equipment upon the return 

of  such  equipment  to  any  Inhep  Electronics  Holdings  branch.  
This  warranty  applies  ONLY  to  defects  in  components  and     
workmanship  and  NOT  to  damage  due  to  causes  beyond  the 
control of Inhep Electronics Holdings, such as incorrect voltage, 
lightning damage, mechanical shock, water damage, fire damage 
or damage arising out of abuse and improper application of the 
equipment. 

  
  

NOTE: Wherever possible, return only the PCB to                     

Inhep Electronics Holdings service centres. 

DO NOT return the enclosure. 

  

The IDS Ezi4 Alarm Panel is a product of                                               

IDS (Inhep Digital Security) and is manufactured by                                                  

Inhep Electronics Holdings (Pty) Ltd 

  

  

WARNING 

For safety reasons, only connect equipment with a         

telecommunications compliance label.  This includes     

customer equipment previously labeled permitted             

or certified. 

91 Escom Road  •  New Germany • 3610 • South Africa • P O Box 738 • New Germany • 3620 • South Africa 

Tel: +27 (0)31 705 1373  

 Fax: +27 (0)31 705 4445 

 e-mail: [email protected] 

  www.inhep.com 

 

INHEP ELECTRONICS HOLDINGS (Pty) Ltd 

Reg. No. 2007/002578/07

 

 

Summary of Contents for Ezi4

Page 1: ...IDS Ezi4 Alarm Panel Installer Manual SOUTH AFRICA S LEADING MANUFACTURER AND DISTRIBUTOR OF ELECTRONIC SECURITY PRODUCTS ...

Page 2: ...ou years of problem free security The Ezi4 Alarm Panel is designed for small simple low cost installations with limited monitoring requirements It is easy to install and requires no programming to operate It is ideally suited to novice and DIY installers Zone Status information is displayed on five light emitting diodes mounted on the lid of the panel The panel also includes the following 1 x Arm ...

Page 3: ...or Input End of Line Terminated Zone Circuits 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal 3K3 ZONE INPUT Terminal Normally Closed Contact with 3K3 Terminating Resistor Normally Open Contact with 3K3 Terminating Resistor Normally Open Contact and Normally Closed Contact with 3K3 terminating Resistor 3K3 Resistor Terminating an Unused Zone Typical EOL Zone Circuits Transf...

Page 4: ...ipherals are connected and what battery is used The battery must be connected to the Red Positive and Black Negative battery leads on the panel as shown The panel is polarity protected via a 1A fastblow fuse The auxiliary power supply on the Ezi4 alarm panel is used to supply power to any peripheral hardware passive infra red detectors remote receivers etc that connects to the panel It is labelled...

Page 5: ...nd is labelled Tamper reference Fig 1 A normally closed switch or contact must be connected to this input in order to operate correctly If unused ensure that a jumper is placed across the contact Failure to add a jumper across this output will prevent the panel from arming This is indicated via the power LED blinking at a faster rate of four times in on second versus once per second in a normal st...

Page 6: ...ate If the output is OFF the panel is in the disarmed state PGM Outputs 2 When a new Alarm condition is generated PGM 2 will turn on momentarily for 1 second This output is designed to link the Ezi4 Alarm Panel to either a communicator input or to link the Ezi4 Alarm Panel to another panel Display Five Light emitting diodes LEDs are mounted on the lid of the alarm panel as shown in figure 4 below ...

Page 7: ...ll flash once per second If the tamper input open the power led will flash four times per second Violating a Zone A zone is considered violated by the panel if it is shorted to or opened for a period exceeding 300mS This makes the Ezi4 alarm panel zone input suitable for most sensor types with the exception being vibration switches Arming the Panel The Ezi4 alarm panel will enter the armed state i...

Page 8: ...water damage fire damage or damage arising out of abuse and improper application of the equipment NOTE Wherever possible return only the PCB to Inhep Electronics Holdings service centres DO NOT return the enclosure The IDS Ezi4 Alarm Panel is a product of IDS Inhep Digital Security and is manufactured by Inhep Electronics Holdings Pty Ltd WARNING For safety reasons only connect equipment with a te...