IDS816 User Manual 700-283-01H Issued January 2009
21
3.
Entering a
[ZONE NUMBER]
will toggle the corresponding LED. For example,
[2] [*]
will turn
LED 2 on (if it was off) and off (if it was on). (Flashing zone LED’s indicate zones that have been
set as Buzz zones and therefore cannot be changed in this menu)
4.
Turn on the LED’s corresponding to the zones you need to be Stay zones. The LED zone
indicators should now indicate only the zones that you require to be Stay zones.
5.
Once satisfied with your selection, press the
[#]
key to exit the Stay zone mode.
NOTE:
Panic zones cannot be selected as Stay zones.
*Buzz zones (shown by flashing indicators, See page 20), cannot be selected as Stay zones. The Buzz
status must be cleared first.
15.
15.
15.
15.
Buzz Zones
Buzz Zones
Buzz Zones
Buzz Zones
Violation of a buzz zone when Stay Armed will cause the keypad buzzer to sound for a period of 30
seconds during which time a valid user code must be entered. If a valid user code is not entered during
this period, the system will register an alarm condition. This feature helps prevent unnecessary false
alarms.
NOTE:
If an Entry/Exit zone is programmed as a Buzz zone, violation of the Entry/Exit zone (when the panel is
Stay Armed) will cause the keypad buzzer to sound for the duration of the entry delay time (in place of the
default 30 seconds). This, if the panel is Stay Armed, allows the user to enter the premises and disarm
the panel. If it is not programmed as a Buzz zone, the alarm will be triggered immediately. If the panel
was armed using the
[6]
key (Stay Arm and Go) violation of the Entry/Exit zone will always start the
Entry/Exit delay.
15.1
15.1
15.1
15.1
How to Program a Buzz Zone
How to Program a Buzz Zone
How to Program a Buzz Zone
How to Program a Buzz Zone
After selecting the required stay profile (Page 19),
Hold down the [4] key until the beep,
then enter [ZONE NUMBER] [*] [#]
1.
Select the required stay profile (See Page 19)
2.
Hold down the
[4]
key until the keypad buzzer sounds. The AWAY indicator will flash indicating
that the panel is in the Buzz zone programming mode.
3.
Entering a
[ZONE NUMBER]
will toggle the corresponding LED. For example,
[2] [*]
will turn
LED 2 on (if it was off) and off (if it was on). (Flashing zone LED’s indicate zones that have been
set as Stay zones and therefore cannot be changed in this menu)
4.
Turn on the LED’s corresponding to the zones you need to be Buzz zones. The LED zone
indicators should now indicate only the zones that you require to be Buzz zones.
5.
Once satisfied with your selection, press the
[#]
key to exit the Buzz zone mode.
NOTE
::::
Panic zones cannot be set as Buzz zones.
Summary of Contents for 816
Page 1: ...IDS816 User Manual 700 283 01H Issued January 2009 1...
Page 4: ...IDS816 User Manual 700 283 01H Issued January 2009 4...
Page 5: ...IDS816 User Manual 700 283 01H Issued January 2009 5...
Page 26: ...IDS816 User Manual 700 283 01H Issued January 2009 26...
Page 28: ...IDS816 User Manual 700 283 01H Issued January 2009 28...