Hold down the [*] key until the beep, 

then enter [MASTER CODE] [*] [1] [1] [*] [SLOT NUMBER] [*] [#] 

 
1.

 

Enter the User Program Mode as per steps 1 to 4 on page 14. 

2.

 

Press  the 

[1]

  key  then  the 

[1]

  key  again  followed  by  the

 

[*]

  key  to  select  menu  option  11.  The 

ARMED and READY indicators will flash simultaneously. 

3.

 

Enter the

 

[SLOT NUMBER]

 followed by the

 

[*]

 key. 

4.

 

The user name will be displayed. Default names are displayed as the SLOT NUMBER (i.e. If the 
SLOT NUMBER has not been edited as per Option 1) 

5.

 

Press 

[#]

 

to exit User Program Mode. 

 

14.          

14.          

14.          

14.                                                        

                                              

                                              

                                              Stay Zones

Stay Zones

Stay Zones

Stay Zones                                       

                                       

                                       

                                                       

                

                

                    

 
Stay  zones  are  those  zones  that  are  bypassed  automatically  when  the  system  is  “STAY  ARMED”.  To 
avoid  triggering  the  alarm,  zones  such  as  bedrooms  that  are  protected  by  Passive  Infra-Red  (PIR) 
detectors or windows that may be opened, must be bypassed when “staying at home”.  
 

Stay zones need only be programmed once. Each time the system is armed in the Stay Mode 

the  pre-selected  stay  zones  will  be  bypassed  automatically.  The  panel  allows  for  two  unique  STAY 
PROFILES to be stored. A STAY PROFILE stores a pre-selected combination of STAY and BUZZ zones to 
suit a specific STAY ARM requirement.  
 

If  a  partition  is  stay  armed  using  Profile  one,  it  is  possible  to  toggle  the  panel  arm  status 

directly to Stay Arm Profile two by holding the 

[5]

 key for two seconds. STAY and BUZZ zones can be 

programmed for each profile once the profile has been selected (below). 

 

14.1         

14.1         

14.1         

14.1                                         

                                

                                

                                How to Select a Stay Profile

How to Select a Stay Profile

How to Select a Stay Profile

How to Select a Stay Profile                                          

                                          

                                          

                                              

 

Hold down the [MODE] key until the beep, 

then enter [2] [*] [PROFILE NUMBER] [*] 

 
1.

 

Ensure that the Panel is disarmed. 

2.

 

Press the

 

[#]

 key to clear any previous entries. 

3.

 

Hold 

[MODE]

 down for one second until the keypad beeps. 

4.

 

Press the 

[2]

 key followed by the 

[*]

 

key. 

5.

 

Press 

[1]

 or 

[2]

 for the required profile. 

6.

 

Press 

[*]

 to enter. The buzzer will give a long beep. 

7.

 

Program STAY and BUZZ zones for the profile (See pages 19 and 20) or ARM the profile  

 

 

14.2       

14.2       

14.2       

14.2                                        

                                 

                                 

                                 How to Program Stay Zones

How to Program Stay Zones

How to Program Stay Zones

How to Program Stay Zones                

                

                

                                            

                            

                            

                                

 

After selecting the required stay profile (Page 19), 

Hold down the [3] key until the beep, 

then enter [ZONE NUMBER] [*] [#] 

 
1.

 

Select the required stay profile (See Page 19) 

2.

 

Hold  down  the 

[3]

  key  until  the  keypad  buzzer sounds. The  AWAY  indicator  will  flash  indicating 

that the panel is in the Stay zone programming mode. 

Summary of Contents for 816

Page 1: ...IDS816 User Manual 700 283 01H Issued January 2009 1...

Page 2: ...el 12 7 1 How to Disarm with a User Code 12 7 2 How to Disarm Using a Key switch or Remote 12 8 Bypassing Zones 13 8 1 Bypassing Un bypassing a Zone 13 9 Emergency Alarms 13 9 1 Fire Alarms 13 9 2 Pan...

Page 3: ...a User Name Option 11 Slot Known 20 14 Stay Zones 20 14 1 How to Select a Stay Profile 20 14 2 How to Program Stay Zones 20 15 Buzz Zones 21 15 1 How to Program a Buzz Zone 21 16 Chime Zones 22 16 1 H...

Page 4: ...IDS816 User Manual 700 283 01H Issued January 2009 4...

Page 5: ...IDS816 User Manual 700 283 01H Issued January 2009 5...

Page 6: ...in most cases Follower Zone A zone that may be temporarily violated during the Exit Zone delay period or after a violation of an Entry Exit zone This allows the user limited time access to disarm the...

Page 7: ...Panels must be used in conjunction with the specified transformer battery combination and appropriate peripheral sensors and signalling devices 2 2 2 2 Before O Before O Before O Before Operating Y p...

Page 8: ...d On System Armed Off System Disarmed Flashing Alarm Condition Check Alarm Memory zone details BEFORE re arming 2 AWAY Indicator Red On System Armed in Away Mode Off System Disarmed Armed in Stay Mode...

Page 9: ...e volume for this example to the soft setting press the and 1 key simultaneously for 1 second long press After a 1 second time lapse the keypad will respond with a beep at the new volume setting This...

Page 10: ...ly holding down the 1 key until the keypad buzzer sounds and the arming process begins NOTE If the partition is already STAY armed this key will initialise AWAY arming It is therefore possible to chan...

Page 11: ...STAY arm by holding down the 5 key until the keypad buzzer sounds The panel will immediately arm into the stay mode without any exit delay All stay zones will be bypassed N N N NOTE OTE OTE OTE Holdi...

Page 12: ...a with a U U U User ser ser ser C C C Code ode ode ode USER CODE 1 Enter the premises through a designated entry route Entering via any other route will cause an alarm 2 As soon as the Entry Exit zone...

Page 13: ...turn LED 2 on if it was off and off if it was on 4 Turn on the LED s corresponding to the zones you need to bypass The LED zone indicators should now indicate only the zones that require bypassing 5...

Page 14: ...e to disarm the system under duress When a DURESS CODE is entered the control panel disarms A Duress Alarm Code if programmed will be reported to the monitoring company but the siren will not sound It...

Page 15: ...ed by LCD keypads This option is only applicable if LCD keypads are installed Option 2 Allows editing of a selected user code Note that the user code properties are not edited only the user code itsel...

Page 16: ...it a User Name Edit a User Name Option 1 LCD Keypads O Option 1 LCD Keypads O Option 1 LCD Keypads O Option 1 LCD Keypads Only nly nly nly Hold down the key until the beep then enter MASTER CODE 1 Use...

Page 17: ...perties Properties Properties Properties Option 4 Option 4 Option 4 Option 4 Hold down the key until the beep then enter MASTER CODE 4 USER CODE PROPERTY No 1 Enter the User Program Mode as per steps...

Page 18: ...D S CODE 13 5 1 3 13 5 1 3 13 5 1 3 13 5 1 3 G G G Global lobal lobal lobal A A A Arm rm rm rm D D D Disarm isarm isarm isarm C C C Code ode ode ode This code when entered will either arm or disarm th...

Page 19: ...e Code K K K Known nown nown nown Hold down the key until the beep then enter MASTER CODE 9 USER CODE 1 Enter the User Program Mode as per steps 1 to 4 on page 14 2 Press the 9 key followed by the key...

Page 20: ...ally The panel allows for two unique STAY PROFILES to be stored A STAY PROFILE stores a pre selected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay a...

Page 21: ...s Stay Armed will cause the keypad buzzer to sound for the duration of the entry delay time in place of the default 30 seconds This if the panel is Stay Armed allows the user to enter the premises and...

Page 22: ...it was off and off if it was on 4 Turn on the LED s corresponding to the zones you need to be CHIME zones The LED zone indicators should now indicate only the zones that you require to be CHIME zones...

Page 23: ...keypad beeps 3 Press 1 followed by the PARTITION NUMBER If no key is pressed on the keypad for specified delay period default is 20 seconds the keypad will beep and default back to its original partit...

Page 24: ...B B B B Battery 7 23 27 Buzz Zone 8 9 10 20 21 27 Bypass 6 8 10 11 13 14 20 24 27 C C C C Control Panel 7 10 12 14 18 Chime 8 9 22 27 D D D D Disarm 6 8 9 11 12 13 14 18 19 20 21 22 23 24 27 Duress 1...

Page 25: ...e Key switch Reporting Code 6 13 14 18 S S S S Siren 7 9 10 12 13 14 22 23 27 Stay Arm see Arm Stay Arm Go see Arm Stay Mode 8 11 20 Stay Profile 10 11 20 21 22 27 Strobe 12 T T T T Tamper 6 8 9 14 23...

Page 26: ...IDS816 User Manual 700 283 01H Issued January 2009 26...

Page 27: ...User Code Partition Number Teach a Remote to a User Code Master Code 8 User Code Press Tx Button Delete a User Code by Code Master Code 9 User Code Delete a User Code by Slot Number Master Code 10 Sl...

Page 28: ...IDS816 User Manual 700 283 01H Issued January 2009 28...

Reviews: