IDS 816 User Manual Download Page 18

 

IDS816 User Manual   700-283-01H   Issued January 2009 

 

18 

 

 

Table 2  User Code Properties 

 

Zone

Zone

Zone

Zone LED

 LED

 LED

 LED    

Property

Property

Property

Property    

Duress code 

Arm to disarm code [Maid’s code] 

Global arm/disarm code 

 

13.5.1     

13.5.1     

13.5.1     

13.5.1                              

                         

                         

                         Explanation of 

Explanation of 

Explanation of 

Explanation of U

U

U

User Code

ser Code

ser Code

ser Code Properties

 Properties

 Properties

 Properties                                  

                                  

                                  

                                      

 

13.5.1.1        

13.5.1.1        

13.5.1.1        

13.5.1.1                                      

                              

                              

                                    

      

      

           

     

     

     Duress Code

Duress Code

Duress Code

Duress Code                    

                    

                    

                                                   

                               

                               

                                   

 

 

This is a special 4 (default) or 6 digit user code (check the code length with your installer) which 
should  only  be  used  in  the  unique  situation  where  an  intruder  forces  one  to  disarm  the  system 
“under duress”. 

 

When  the  DURESS CODE is  entered,  the  control  panel  disarms  normally  -  however,  a  DURESS 
REPORTING CODE is transmitted to the monitoring company to inform them that you have been 
forced to disarm the control panel by an intruder. 

 

It is advisable to choose a code that can be easily remembered by all family (or staff) members.  

 

13.5.1.2       

13.5.1.2       

13.5.1.2       

13.5.1.2                                                 

                                          

                                          

                                          Maid’s Code

Maid’s Code

Maid’s Code

Maid’s Code                                                      

                                                      

                                                      

                                                          

 
This code may be used to limit access to the premises. The MAID’S CODE will only disarm the system if 
the same code was used for arming. If armed with a code other than this code, the system will view an 
attempt to disarm using the MAID’S CODE as an invalid entry. Any valid user code will disarm the system 
if it has been armed with the MAID’S CODE. 
 

 

13.5.1.3         

13.5.1.3         

13.5.1.3         

13.5.1.3                                       

                              

                              

                              G

G

G

Global

lobal

lobal

lobal A

 A

 A

 Arm

rm

rm

rm/D

/D

/D

/Disarm

isarm

isarm

isarm C

 C

 C

 Code

ode

ode

ode                                          

                                          

                                          

                                              

 
This code, when entered, will either arm or disarm the partitions assigned to that user depending on their 
status. If both partitions are disarmed, entering a global code will arm both partitions. If both partitions are 
armed, entering a global code will disarm them. In the case where one partition is armed and the other 
disarmed,  entering  a  global  code  at  the  keypad  of  the  armed  partition  will  disarm  that  partition  and 
entering a global code at the keypad of the disarmed partition will arm that partition. 
 

13.6       

13.6       

13.6       

13.6                           

                    

                    

                    Assign 

Assign 

Assign 

Assign a 

a U

U

U

User

ser

ser

ser C

 C

 C

 Code

ode

ode

ode to Partitions

 to Partitions

 to Partitions

 to Partitions    –

––

– Option 5

 Option 5

 Option 5

 Option 5                

                

                

                             

             

             

                 

 

Hold down the [*] key until the beep, 

then enter [MASTER CODE] [*] [5] [*] [USER CODE] [*] [ZONE LED No] [*] [#]

 

 
1.

 

Enter the User Program Mode as per steps 1 to 4 on page 14. 

2.

 

Press  the 

[5]

  key  followed  by  the 

[*]

 

key  to  select  programmable  option  5.  The  READY  and 

ARMED LED’s will flash simultaneously. 

3.

 

Enter the 

[USER CODE]

 followed by the 

[*]

 key. 

4.

 

The READY indicator will flash and the AWAY indicator will be on. 

5.

 

The partitions to which the user code is assigned are displayed by the by the zone LED’s. If zone 
LED 1 is on, the user code can arm or disarm partition 1. If zone LED 2 is on, the user code can 
arm or disarm partition 2. It is possible to program codes to arm/disarm both partitions. 

6.

 

To  select  which  partitions  the  user  code  may  arm  or  disarm,  toggle zone  LED’s by  entering  the 

[ZONE LED NUMBER]

 followed by the 

[*]

 

key. 

Summary of Contents for 816

Page 1: ...IDS816 User Manual 700 283 01H Issued January 2009 1...

Page 2: ...el 12 7 1 How to Disarm with a User Code 12 7 2 How to Disarm Using a Key switch or Remote 12 8 Bypassing Zones 13 8 1 Bypassing Un bypassing a Zone 13 9 Emergency Alarms 13 9 1 Fire Alarms 13 9 2 Pan...

Page 3: ...a User Name Option 11 Slot Known 20 14 Stay Zones 20 14 1 How to Select a Stay Profile 20 14 2 How to Program Stay Zones 20 15 Buzz Zones 21 15 1 How to Program a Buzz Zone 21 16 Chime Zones 22 16 1 H...

Page 4: ...IDS816 User Manual 700 283 01H Issued January 2009 4...

Page 5: ...IDS816 User Manual 700 283 01H Issued January 2009 5...

Page 6: ...in most cases Follower Zone A zone that may be temporarily violated during the Exit Zone delay period or after a violation of an Entry Exit zone This allows the user limited time access to disarm the...

Page 7: ...Panels must be used in conjunction with the specified transformer battery combination and appropriate peripheral sensors and signalling devices 2 2 2 2 Before O Before O Before O Before Operating Y p...

Page 8: ...d On System Armed Off System Disarmed Flashing Alarm Condition Check Alarm Memory zone details BEFORE re arming 2 AWAY Indicator Red On System Armed in Away Mode Off System Disarmed Armed in Stay Mode...

Page 9: ...e volume for this example to the soft setting press the and 1 key simultaneously for 1 second long press After a 1 second time lapse the keypad will respond with a beep at the new volume setting This...

Page 10: ...ly holding down the 1 key until the keypad buzzer sounds and the arming process begins NOTE If the partition is already STAY armed this key will initialise AWAY arming It is therefore possible to chan...

Page 11: ...STAY arm by holding down the 5 key until the keypad buzzer sounds The panel will immediately arm into the stay mode without any exit delay All stay zones will be bypassed N N N NOTE OTE OTE OTE Holdi...

Page 12: ...a with a U U U User ser ser ser C C C Code ode ode ode USER CODE 1 Enter the premises through a designated entry route Entering via any other route will cause an alarm 2 As soon as the Entry Exit zone...

Page 13: ...turn LED 2 on if it was off and off if it was on 4 Turn on the LED s corresponding to the zones you need to bypass The LED zone indicators should now indicate only the zones that require bypassing 5...

Page 14: ...e to disarm the system under duress When a DURESS CODE is entered the control panel disarms A Duress Alarm Code if programmed will be reported to the monitoring company but the siren will not sound It...

Page 15: ...ed by LCD keypads This option is only applicable if LCD keypads are installed Option 2 Allows editing of a selected user code Note that the user code properties are not edited only the user code itsel...

Page 16: ...it a User Name Edit a User Name Option 1 LCD Keypads O Option 1 LCD Keypads O Option 1 LCD Keypads O Option 1 LCD Keypads Only nly nly nly Hold down the key until the beep then enter MASTER CODE 1 Use...

Page 17: ...perties Properties Properties Properties Option 4 Option 4 Option 4 Option 4 Hold down the key until the beep then enter MASTER CODE 4 USER CODE PROPERTY No 1 Enter the User Program Mode as per steps...

Page 18: ...D S CODE 13 5 1 3 13 5 1 3 13 5 1 3 13 5 1 3 G G G Global lobal lobal lobal A A A Arm rm rm rm D D D Disarm isarm isarm isarm C C C Code ode ode ode This code when entered will either arm or disarm th...

Page 19: ...e Code K K K Known nown nown nown Hold down the key until the beep then enter MASTER CODE 9 USER CODE 1 Enter the User Program Mode as per steps 1 to 4 on page 14 2 Press the 9 key followed by the key...

Page 20: ...ally The panel allows for two unique STAY PROFILES to be stored A STAY PROFILE stores a pre selected combination of STAY and BUZZ zones to suit a specific STAY ARM requirement If a partition is stay a...

Page 21: ...s Stay Armed will cause the keypad buzzer to sound for the duration of the entry delay time in place of the default 30 seconds This if the panel is Stay Armed allows the user to enter the premises and...

Page 22: ...it was off and off if it was on 4 Turn on the LED s corresponding to the zones you need to be CHIME zones The LED zone indicators should now indicate only the zones that you require to be CHIME zones...

Page 23: ...keypad beeps 3 Press 1 followed by the PARTITION NUMBER If no key is pressed on the keypad for specified delay period default is 20 seconds the keypad will beep and default back to its original partit...

Page 24: ...B B B B Battery 7 23 27 Buzz Zone 8 9 10 20 21 27 Bypass 6 8 10 11 13 14 20 24 27 C C C C Control Panel 7 10 12 14 18 Chime 8 9 22 27 D D D D Disarm 6 8 9 11 12 13 14 18 19 20 21 22 23 24 27 Duress 1...

Page 25: ...e Key switch Reporting Code 6 13 14 18 S S S S Siren 7 9 10 12 13 14 22 23 27 Stay Arm see Arm Stay Arm Go see Arm Stay Mode 8 11 20 Stay Profile 10 11 20 21 22 27 Strobe 12 T T T T Tamper 6 8 9 14 23...

Page 26: ...IDS816 User Manual 700 283 01H Issued January 2009 26...

Page 27: ...User Code Partition Number Teach a Remote to a User Code Master Code 8 User Code Press Tx Button Delete a User Code by Code Master Code 9 User Code Delete a User Code by Slot Number Master Code 10 Sl...

Page 28: ...IDS816 User Manual 700 283 01H Issued January 2009 28...

Reviews: