31
NOTE:
When connecting any device with a high current requirement to a programmable output a suitable relay
must be used. DO NOT connect such devices directly to the programmable outputs as this may damage
the output circuitry.
LOCATIONS 70-87
Event Driven Programmable Outputs
Table 7 : Event Driven Programmable Outputs
Loc.
Event
Output
Default Action
70
AC fail programmable output
Disabled
71
AC restore programmable output
Disabled
72
Low battery programmable output
Disabled
73
Battery restore programmable output
Disabled
74
Auto test programmable output
Disabled
75
Download programmable output
Disabled
76
Siren trouble programmable output
Disabled
77
Aux 12V trouble programmable output
Disabled
78
Keypad fuse programmable output
Disabled
79
485 device tamper programmable output
Disabled
80
485 bus failure programmable output
Disabled
81
Box tamper programmable output
Disabled
82
Dedicated panic programmable output
1
Pulse high [2]
83
Communication fail programmable output
Disabled
84
Phone line tamper programmable output
Disabled
85
Phone line restore programmable output
Disabled
86
RF jamming programmable output
Disabled
87
RF jamming restore programmable
output
Disabled
LOCATIONS 95 – 96
Function Driven Programmable Outputs
Table 8 : Function Driven Programmable Outputs
Summary of System function Driven Programmable outputs
Loc.
Function
Output
95
Fire sensor power programmable output Disabled
96
Dual reporting programmable output
Disabled
Summary of Contents for 816
Page 1: ......
Page 2: ...IDS 816 700 283 02I Issued September 2009 2...
Page 6: ...IDS 816 700 283 02I Issued September 2009 6...
Page 7: ...IDS 816 700 283 02I Issued September 2009 7...
Page 61: ...IDS816 User Manual 700 283 01H Issued January 2009...
Page 62: ...IDS816 User Manual 700 283 01H Issued January 2009...
Page 64: ...IDS816 User Manual 700 283 01H Issued January 2009...